Daikin Altherma Weather Curve: How to Set It Up

Last reviewed: November 2026. Help for Daikin Altherma owners.

Short answer

Weather compensation, which Daikin calls weather dependent operation, lets your Altherma set its water temperature from the outdoor temperature. Colder outside means warmer water to your radiators or floors. Milder weather means cooler water and lower running costs. You fine tune it with the slope and offset settings, making one small change at a time.

Graph of a weather compensation curve showing water temperature rising as outdoor temperature falls
As it gets colder outside, the curve asks for warmer water.

What weather compensation does

Daikin’s user reference guide explains that in weather dependent mode the desired leaving water temperature is set automatically from the outdoor temperature, measured by a sensor. When it gets colder or milder outside, the unit adjusts straight away instead of waiting for a room thermostat to react. Daikin says this reduces energy consumption and helps avoid big swings in room temperature.

Why lower water temperatures save money

A heat pump works more efficiently when it makes cooler water. A well set curve sends water that is just warm enough to keep your home comfortable on each day. On mild days that can be much cooler than a fixed setting. Our guide to leaving water temperature explains more.

The two types of Daikin weather curve

On Altherma 3 models with the current user interface there are two curve types:

  • Slope-offset curve, which is the default. You adjust a slope and an offset.
  • 2-points curve. You set the water temperature you want at two outdoor temperatures and the unit draws a line between them.

The curve type applies to all zones. Daikin’s guide lists it under Main zone > WD curve type.

Slope and offset explained

Two graphs comparing a weather curve slope change with an offset change
Offset moves the whole line. Slope changes how steep it is.
  • Offset raises or lowers the water temperature by the same amount at every outdoor temperature. Daikin’s example: if the water is always a bit too cold, shift the offset up.
  • Slope changes how much warmer the water gets as it gets colder outside. Daikin’s example: if the water is fine in general but too cold on cold days, raise the slope.

How to switch on and adjust the weather curve

These menu names come from Daikin’s user reference guide for Altherma 3 models with the current user interface. Older models, the Madoka controller and the Onecta app may look different. Some options may be hidden depending on the permission level your installer set.

  1. Check the setpoint mode. Go to Main zone > Setpoint mode and choose Weather dependent, or WD heating, fixed cooling if your system also cools.
  2. Open the curve. Go to Main zone > Heating WD curve.
  3. Choose slope or offset and change it by one step.
  4. Confirm and leave it alone while you see how the house responds.
  5. Repeat for any additional zone using Additional zone > Heating WD curve.

The tank has its own weather dependent option, but Daikin restricts it to installers. Leave tank settings to your installer.

How to tune your curve, step by step

Simple log sheet for recording weather curve changes and room temperatures
Keep a note of each change, the weather and how the rooms felt.

This method is common practice among heat pump owners and engineers. It is not a Daikin procedure.

  1. Make one change at a time. Change either slope or offset, never both together.
  2. Use small steps. One step at a time is enough.
  3. Wait. Heat pumps and underfloor heating respond slowly. Give each change at least a day, longer with underfloor heating.
  4. Keep notes. Write down the outdoor temperature, the change and how the rooms felt.
  5. Use this rule of thumb:
    • Too cold in all weather: raise the offset.
    • Too warm in all weather: lower the offset.
    • Fine when mild but too cold when it is cold outside: raise the slope.
    • Fine when mild but too warm when it is cold outside: lower the slope.
  6. Aim for the lowest curve that keeps you comfortable. That is usually the cheapest to run.

Signs your weather curve needs adjusting

How the room thermostat fits in

Depending on how your system is set up, a room thermostat may switch heating on and off or adjust the water temperature too. If the thermostat is set low, it can stop the heating before the curve has a chance to work. Check our room thermostat guide if the two seem to fight each other.

When to call an engineer

Weather curve changes are user settings, so you can usually try them yourself. Ask a qualified heat pump engineer or your installer to help if:

  • you need a very high curve to stay warm, which can mean radiators are too small or the system is not balanced
  • the setpoint mode or curve menus are locked or missing
  • you want the tank on weather dependent control
  • you see error codes or the heat pump keeps short cycling after changes

Daikin notes that the leaving water temperature is set by your installer to suit your radiators or floors, so only make big changes if you have a problem.

Book a heat pump engineer

FAQs

What is weather dependent mode on a Daikin Altherma?

It is Daikin’s name for weather compensation. The heat pump sets its water temperature from the outdoor temperature, so it sends warmer water when it is cold and cooler water when it is mild.

Should I change the slope or the offset first?

If you are too warm or too cold in all weather, change the offset. If you are only uncomfortable when it is cold outside, change the slope. Change one thing at a time.

How long should I wait after changing the weather curve?

Give each small change at least a day so the house can settle. With underfloor heating, wait longer, as it responds slowly.

Does weather compensation save money?

Daikin says weather dependent operation reduces energy consumption. Lower water temperatures make the heat pump more efficient, so a well set curve usually costs less to run.

Can I set the hot water tank to weather dependent?

Daikin lists weather dependent control for the tank as an installer only setting. Ask your installer if you want it changed.

Sources we checked

This is general guidance only. For faults or anything electrical, please contact a qualified heat pump engineer or Daikin directly.

Ask My Heat Pump is an independent support site. We are not affiliated with, endorsed by or sponsored by Daikin.