Last reviewed: November 2026. Help for Daikin Altherma owners.
Short answer
The most common reasons a Daikin Altherma uses more electricity than expected are water temperatures set higher than needed, the backup or booster heater running, hot water heated too hot or too often and cold weather. Most of these can be improved with user settings. If the backup heater is running a lot, or the unit switches on and off constantly, ask your installer to check the setup.
First, is your usage really high?
A heat pump uses most of its electricity in the coldest months, so a big January bill is not always a fault. Before you change anything:
- Take a daily meter or app reading for a week or two. Some Altherma setups show energy use on the controller or in the Onecta app, but this depends on your model and setup.
- Note the outdoor temperature each day.
- Compare cold days with mild days. Usage should drop clearly when the weather is milder.
If usage stays high on mild days, one of the causes below is likely.
The most common causes
1. Water temperatures are higher than they need to be
This is the biggest one. Daikin says a lower leaving water temperature in heating mode means lower energy consumption and better performance. Daikin’s own data for the Altherma 3 H HT shows how big the difference is. At 7°C outside the published COP is 4.86 with 35°C water and 3.05 with 55°C water. So the same heat costs far more at higher water temperatures.
What to check: make sure you are on weather dependent control and lower the curve in small steps. See our weather curve guide.
2. The backup or booster heater is running
Electric backup and booster heaters turn every unit of electricity into one unit of heat, so they cost much more to run than the heat pump itself. They can run when:
- powerful operation is switched on for hot water
- the hot water temperature is set above what the heat pump can reach alone
- the heat pump has a fault and the backup heater takes over as an emergency heater, which Daikin describes in its user guides
- the system is set up to use the backup heater in cold weather
What to check: look for backup or booster heater symbols on the controller. See our guides to the backup heater and display symbols. If it runs often, ask your installer to review the settings. Do not change backup heater settings yourself.
3. Hot water is too hot or heated too often
Daikin advises lowering the tank temperature by 1°C a day until it just meets your needs. On the Altherma 3 H HT, Daikin says the heat pump alone can reach 63°C, or 57°C in cold weather. Above that an electric heater adds the rest. Limits differ by model.
4. The room temperature is set high
Daikin’s energy saving tips say each degree you save can cut heating costs by up to 6%. Turning the thermostat up does not heat the room faster.
5. Cold weather and defrost
Daikin notes that the higher the outdoor temperature, the better the heat pump performs. In cold, damp weather the outdoor unit also needs to defrost from time to time, which uses some energy. Higher winter use is normal.
6. The heat pump switches on and off a lot
Frequent on and off running, called short cycling, is widely reported by owners as a cause of poor efficiency. It can come from a unit that is large for the home, many closed radiators or a curve set too high. This is based on owner and engineer reports rather than a Daikin figure, so treat the size of the effect as uncertain.
7. The weekly disinfection cycle
The legionella cycle heats the tank to a higher temperature, usually once a week. It uses some extra electricity. Leave it on, but ask your installer to schedule it at a cheaper time if your tariff varies.
8. Your tariff and timing
Daikin recommends heating hot water at night if electricity is cheaper then. Matching hot water schedules to cheaper times can lower bills without using less energy. See our tariff guide.
Quick wins you can try today
- Switch to weather dependent control if you are on a fixed water temperature.
- Lower the curve offset by one step and see how the house feels after a day or two.
- Lower the hot water temperature by 1°C a day.
- Only use powerful operation when you really need it.
- Keep radiators and zones open where you can, so the heat pump runs steadily.
- Keep the outdoor unit clear of leaves, snow and plants.
For more, read ways to cut Daikin Altherma running costs and our best settings guide.
When to call an engineer
Ask your installer or a qualified heat pump engineer to check your system if:
- usage stays high on mild days after you have tried the quick wins
- you often see the backup or booster heater symbol
- the heat pump switches on and off every few minutes
- you see error codes, especially flow or refrigerant codes
- a breaker trips or anything electrical seems wrong
FAQs
Why is my Daikin Altherma using so much electricity?
The usual causes are water temperatures set higher than needed, the backup or booster heater running, hot water set too hot and cold weather. Checking your weather curve and hot water settings is the best place to start.
Is it normal for a heat pump to use more electricity in winter?
Yes. Daikin notes that heat pumps perform better when it is warmer outside. Use rises in cold weather, partly because of defrost cycles.
How do I know if the backup heater is running?
Look for the backup or booster heater symbol on the controller. If you see it often, ask your installer to check how and when it is allowed to run.
Does lowering the hot water temperature save money?
Yes. Daikin says the lower the tank temperature, the more cost effective it is. Lower it by 1°C a day until it just meets your needs.
Should I switch my heat pump off when I go out?
Usually not for short periods. Big temperature drops can cost more to recover, especially with underfloor heating. Use holiday mode for longer trips.