Aira Heat Pump Not Heating: Owner Checks

If your home feels cold, a few simple checks in the Aira Home Energy app and around the house often explain it. Aira recommends these before you contact customer care.

Check the app and thermostat

  • Open Indoor temperature in the app. Check the target temperature, and that Allow Heating is switched on (shown in yellow).
  • Compare the actual temperature on the app or the Aira Thermostat with your target.
  • If the thermostat has lost connection, hold it in front of the indoor unit until it reconnects. If that fails, take out one battery for at least a minute, then put it back.
  • Check Away Mode is not on. It keeps heating to a minimum and pauses hot water.

Check the radiators

  • Make sure radiator valves (TRVs) are fully open, except in rooms you want cooler. Closing too many reduces flow.
  • If you have underfloor heating, check its room thermostats are calling for heat.
  • Bleed radiators that are cold at the top, then check the system pressure.

What is normal

  • The variable-speed compressor slows down and may stop in mild weather. This can look like the heat pump switching on and off.
  • Heat pumps run at lower flow temperatures than boilers, typically 35–55 °C on Aira systems, so radiators feel warm rather than hot.
  • After a power cut, the heat pump restarts by itself.
  • Every Aira system has a backup heater that comes on automatically if the heat pump fails.

FAQ

My radiators are only warm, not hot. Is my Aira broken?

Not necessarily. Aira says flow temperatures are typically 35–55 °C, so radiators run cooler than with a boiler. Check the room reaches its target.

Should I turn my Aira off when I go away?

Aira designs the heat pump to run all year. For absences of three days or more, use Away Mode in the app instead of switching it off.

What to tell Aira customer care

  • Your target and actual room temperatures from the app.
  • Any light on the indoor unit and any alert in the app.
  • Which rooms are cold, and whether hot water still works.
  • Your system pressure reading.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Aira UK customer support: Heating and hot water (retrieved 15 Nov 2026). Official page
  • Aira UK customer support: Thermostat (retrieved 15 Nov 2026). Official page
  • Aira UK customer support: System performance (retrieved 15 Nov 2026). Official page
  • Aira UK customer support: Maintenance (retrieved 15 Nov 2026). Official page

Related guides

Safety first

Owners can change settings in the app, open radiator valves and bleed radiators. Do not open the indoor or outdoor unit: Aira says only its qualified technicians may remove covers.

Still stuck?

Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.

Independent guide, not affiliated with or endorsed by Aira.