Last reviewed: November 2026. Help for Daikin Altherma owners.
Short answer
A Daikin Altherma has a water filter, often a magnetic filter or dirt separator, that catches sludge and debris in the heating water. Daikin’s manuals say it should be cleaned as part of yearly maintenance. They also say that maintenance must be done by an installer or service agent. A dirty filter can cut water flow and trigger 7H error codes. For most owners the right step is booking a yearly service, not opening the filter themselves.
What the filter does
Heating water picks up sludge, rust particles and debris over time, especially in older systems with existing radiators. The filter catches this before it reaches the heat pump’s heat exchanger, pump and flow sensor. Many Altherma indoor units have a built in magnetic filter or dirt separator. Some systems also have a filter in a shut-off valve, or a separate magnetic filter fitted by the installer. Which ones you have depends on your model and installation, so check your paperwork or ask your installer.
How often does it need cleaning?
Daikin’s installation manuals say maintenance must be done by an installer or service agent and recommend it at least once a year. Local rules may require shorter intervals. Cleaning the magnetic filter or dirt separator is listed as part of that yearly maintenance. New systems, or older systems with a lot of sludge, may need it more often in the first year. This is general engineering experience rather than a Daikin figure.
Signs the filter may need cleaning
- 7H water flow error codes, which Daikin lists a dirty filter as a possible cause of
- radiators or floors slower to warm up than usual
- more frequent stops and starts
- it has been more than a year since the last service
These signs can have other causes too, such as air or low pressure, which is why an engineer should diagnose it.
Why this is usually an engineer job
Daikin’s procedures for the filter involve:
- stopping the unit and switching off the circuit breaker
- on some models, opening the indoor unit and lowering the switch box to reach the filter
- draining water from the system into a container
- checking and topping up the system pressure afterwards
Daikin’s service manual for the 3 H HT says the yearly clean is a flush with the valves left open, because system pressure is needed to push the dirt out. Taking the filter apart is only for serious problems. Daikin even says it should preferably never be needed during the filter’s life. Getting the order wrong can lead to leaks, air in the system, low pressure or damage to pipework. Inside the indoor unit there are also electrical parts and hot water.
Our advice: do not open the indoor unit or the built in filter yourself. If your installer has fitted a separate filter and has shown you how to clean it, follow their instructions exactly. If you are unsure, book an engineer.
What you can do as an owner
- Book a yearly service and ask for the filter to be cleaned. See what an annual service covers.
- Keep an eye on the pressure and note any changes. See water pressure.
- Write down any error codes and when they appear.
- Ask about water treatment. If your system has inhibitor or other additives, Daikin notes the levels should be checked after flushing.
- Keep service records. They help with diagnosis and may matter for your warranty. See warranty and servicing.
What else a yearly service should cover
Daikin’s yearly maintenance list includes checking the water pressure, cleaning the magnetic filter or dirt separator, testing the pressure relief valves and inspecting the switch box. A good engineer will also check the outdoor unit and your settings. See our magnetic filter guide for more.
When to call an engineer
Book a qualified heat pump engineer if:
- your system has not been serviced for over a year
- you see 7H or other flow related error codes
- the pressure keeps dropping or you see water leaking
- heating is slow and the basic checks have not helped
FAQs
Where is the filter on a Daikin Altherma?
It depends on the model. Many indoor units have a built in magnetic filter or dirt separator, which on some models sits behind the switch box. Some systems also have separate filters fitted by the installer.
How often should a Daikin Altherma filter be cleaned?
Daikin’s manuals list filter cleaning as part of maintenance recommended at least once a year. Systems with a lot of sludge may need it more often.
Can I clean the Daikin Altherma filter myself?
Daikin says maintenance must be done by an installer or service agent. Cleaning involves switching off power, draining water and sometimes opening the unit, so leave it to an engineer.
Can a dirty filter cause a 7H error?
Yes. Daikin lists a dirty filter in the shut-off valve or a dirty magnetic filter as possible causes of 7H water flow codes.
What happens if the filter is never cleaned?
Sludge can build up and reduce water flow. That can lead to flow error codes, slower heating and extra strain on the pump and heat exchanger.