Ecodan Main Remote Controller Guide (FTC7 Touchscreen)

Ecodan cylinder and hydrobox systems with an FTC7 controller use a touchscreen main remote controller, mounted on the wall or the unit’s front panel. This guide follows Mitsubishi Electric’s operation manual for those units. If you have an older FTC6 controller with buttons, the menus differ, so check your own book.

The home screen

  • It shows the target temperature, space heating mode, hot water mode, any extra heat source in use, holiday mode, and the date and time.
  • Touch the left area for Heating / Cooling, the right area for DHW (hot water), or the menu icon.
  • Some functions are greyed out or hidden, depending on how your system is configured.

Heating modes

There are three heating modes:

  • Room temperature (Auto adaptation): measures room and outdoor temperature and works out the flow temperature needed.
  • Flow temperature: a fixed flow temperature set by the installer.
  • Weather compensation curve: flow temperature follows outdoor temperature.

Zone 1 and Zone 2 targets are changed with + and −. Auto change over switches between heating and cooling from the outdoor temperature, where cooling is fitted.

Hot water screen

Turn Eco mode on or off, and start or cancel Boost. See our Ecodan hot water guide for details.

Menu items

  • Schedule: includes Seasonal (split the year into two seasons) and up to 4 heating programmes per day.
  • Holiday: runs heating and/or hot water at reduced flow temperatures while you’re away.
  • Energy: monthly and yearly consumption and production.
  • Setting: date/time, display, language, room sensors, contact number and touch screen.
  • Service: password-protected for installers.

Good to know

  • Mitsubishi Electric warns that if the system is switched off or the power is disconnected, freeze-stat protection will not operate.
  • The date and time are kept for 3 days without power.
  • Clean the screen with a soft dry cloth, a cloth with mild detergent, or one dampened with ethanol.

FAQ

Which heating mode should I use?

Your installer picks the mode to suit your emitters. Weather compensation is the usual efficient choice. Ask before switching.

Should I switch the Ecodan off in summer?

Use the seasonal schedule or settings rather than cutting power, so protection functions stay active.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Mitsubishi Electric Ecodan cylinder/hydrobox operation manual (FTC7), library 4938: printed p4–8 (PDF p5–9); printed p9 (PDF p10). Official PDF

Related guides

Safety first

Owners can use the main remote controller, check valves and keep the outdoor unit clear. Refrigerant, electrical and service-menu work is for a qualified engineer, and PUZ-WZ units use flammable R290, so they need an engineer competent with it.

Still stuck?

Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.

Independent guide, not affiliated with or endorsed by Mitsubishi Electric.