Defrost is the most common reason owners think their Vaillant heat pump has a problem. In most cases it’s working exactly as designed.
What happens in defrost
- Below about 5 °C outside, the outdoor coil frosts up.
- The unit reverses for up to about 16 minutes, taking heat from the heating water. The indoor unit shows S.516.
- The fan stops, you hear a whoosh as the valve reverses, and clouds of steam come off the unit.
- Radiators may cool briefly.
- The myVAILLANT app may show defrost energy as “cooling”.
When it happens most
At outdoor temperatures below 5 °C, frost can form on the outdoor coil and the unit thaws it automatically. In freezing fog or snow, expect more defrosts and higher consumption.
Water under the unit
Dripping in cold weather is condensate and defrost melt. It needs to drain or soak away so ice doesn’t build up underneath. Keep the base clear.
Worth reporting to your installer
- Ice building up solid on the coil or base that doesn’t clear after defrosts.
- New grinding, rattling, screeching or banging.
- Repeated S.283 (defrost took over 15 minutes) or S.284 (flow too cold during defrost).
- F.741 (return too cold) or F.718 / F.785 (fan blocked).
What helps
- Keep radiator and zone valves open so there’s enough water for defrost.
- Keep grilles clear of leaves, snow and plants. Never poke anything into the fan or chip ice off the fins.
FAQ
Is steam from the unit smoke?
No. It’s normal vapour from defrost.
Why did my radiators go cold for 10 minutes?
Defrost takes heat from the heating water for up to about 16 minutes. They’ll warm up again afterwards.
Related guides
Safety first
Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer. aroTHERM plus and aroTHERM pro units use R290, so refrigerant work needs an engineer competent with flammable refrigerants.