The Altherma 4 H is Daikin’s newest heat pump, using natural refrigerant R290 (propane). It brings a new touchscreen, built-in Wi-Fi and some important safety features.
Models
- EPSK06–14A: launched April 2025.
- EPSKS04/06/07A: compact single-phase models announced January 2026, with 70°C flow at −15°C, operation down to −28°C, factory-fitted anti-freeze valves, a gas sensor with automatic fan, WLAN as standard and remote software updates.
- Indoor: EPSX(B) ECH2O (P30/P50 = 300/500 litres), EPVX floor with tank (“F”) or EPBX wall (“W”).
R290 safety
R290 is flammable, so Altherma 4 has gas sensors indoors and outdoors.
- A0-02: indoor gas sensor detected a leak. A0-26: outdoor gas sensor detected a leak. The unit stops and needs a manual reset.
- If you see either: ventilate, keep ignition sources away, don’t reset or open the unit, and call your installer urgently. For a gas smell from a gas appliance, call 0800 111 999.
- Sensor faults: C0-14/19 (manual), C0-15/20 (automatic) indoor; H0-02/04 (manual), H0-06/07 (automatic) outdoor.
Engineers need R290 competence.
The touchscreen menus
Different from Altherma 3: [1] Main zone, [2] Additional zone, [3] Space heating/cooling, [4] Domestic hot water, [5] Settings, [6] Information, [7] Maintenance mode, [8] Connectivity, [9] Energy, [10] Configuration wizard, [11] Malfunctioning. Users switch on Advanced settings at [5.13]; installer level is separate. Field codes are three digits.
Key settings
- Weather curve [1.8] (2-point), shift [1.27], increase around 0°C [1.26].
- Hot water: [4.1] single heat-up, [4.3] manual setpoint, [4.4] Powerful setpoint.
- Quiet mode [5.2.1]/[5.2.2]; water pipe freeze prevention [5.36].
Minimum flow
Required 20/22/24 l/min (EPSX07/10/14) for start-up, defrost, cooling and backup heater.
Software v4
Version 4 (2026) added per-zone minimum flow, defrost energy compensation [5.33], hot water priority options, and changed manual overrides to end at the next schedule block. New codes include E3-26/27 (low differential pressure in defrost).
Error reset types
Every code shows whether it resets automatically, needs a manual interface reset (installer) or a power cycle.
FAQ
Does Onecta work?
Yes, Wi-Fi is built in (menu [8.3]).
Is 8H-09 a fault?
No, it’s a normal backup heater relay check at start-up.
Does it need glycol?
The EPSKS has factory anti-freeze valves; your installer designs frost protection.