C0 codes relate to sensors, and what they mean depends heavily on which Altherma you have. On Altherma 4 some C0 codes are gas-safety related, so it’s important to know your model first.
What C0 means by model
- Altherma 3, C0-00: flow sensor.
- Altherma 3, C0-01 / C0-02: flow switch or flow sensor (listed on 3 H MT, 3 M 04–08E and others).
- First-generation LT, “C0”: flow switch.
- RoCon HP units, E9011/C0: flow sensor.
- Altherma 4, C0-14 / C0-19: indoor gas sensor fault, manual reset. C0-15 / C0-20: indoor gas sensor fault, automatic reset.
Altherma 3 and older: what to do
The flow sensor tells the unit how much water is moving. Daikin lists sensor work as engineer-only. Before calling:
- Check pressure is above 1 bar and valves are open, because a genuine flow problem should be ruled out.
- Note whether any 7H codes appeared too.
- Photograph the help text and [8.2] history.
An engineer in our group noted on older units that a flow reading that jumps about on the controller can point to a faulty flow sensor, while a steady but very low reading points to a blockage. That’s for your engineer to interpret.
Altherma 4: gas sensor codes
Altherma 4 uses R290 (propane) and has gas sensors indoors and outdoors. C0-14/15/19/20 mean a problem with the indoor sensor itself, not a detected leak. Still, call your installer promptly so gas detection is working. If you see A0-02 or A0-26 (leak detected), ventilate, keep ignition sources away, don’t reset or open the unit and call your installer urgently.
FAQ
Is a C0 code an emergency?
On Altherma 3, no, but the unit may not run properly. On Altherma 4, sensor faults should be dealt with promptly.
Can I clean the flow sensor?
No. That’s inside the unit and is engineer work.
Will a service prevent it?
Cleaning the magnetic filter at the annual service helps keep flow healthy.
What to tell your engineer
A few details make diagnosis faster and can save a second visit:
- Your outdoor and indoor model codes from the rating labels.
- The full code (for example XX-YY), with a photo of the help text and the malfunction history.
- When it happened and what the system was doing: heating, hot water, defrost or starting up.
- The pressure gauge reading, and whether any valves or radiators were recently touched.
- Whether the code cleared on its own, came back after a reset, or appeared alongside other codes.
- Any recent power cuts, storms or very cold, damp weather.
Related guides
Safety first
Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer (F-gas certified for refrigerant work, and R290-competent for Altherma 4).
Still stuck?
Ask the Heat Pump Assistant with your model code and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.