Daikin Altherma 7H-06 Error: Flow in Defrost

7H-06 tends to appear on cold, damp days when the outdoor unit is defrosting. It’s part of Daikin’s 7H family of water flow codes.

What 7H-06 means

On Altherma 3, Hybrid and second-generation LT units, 7H-06 is a water flow problem during cooling or defrost. Its siblings are 7H-01 (general flow problem, resets itself), 7H-04 (during hot water) and 7H-05 (during heating). Unlike 7H-01, 7H-06 stops the unit and needs a manual reset on the interface. On Altherma 4 the defrost-related flow codes are different: 7H-09/10 (emitter or tank defrost).

Why defrost needs good flow

Defrost borrows heat from the water in your heating system to melt ice off the outdoor coil. Daikin therefore sets a minimum flow rate, and if it isn’t reached during defrost you’ll see 7H-06. Examples from Daikin’s guides:

These figures apply only to the models on the cover of the book named in the source block. The Altherma 3 M 04–08 book publishes several minimum flow rates for different operating modes — do not treat 12 l/min as the figure for every 3 M mode or every 3 M size.

Family Operating mode Minimum flow
Altherma 3 R Minimum required flow rate (single published figure) 12 l/min
Altherma 3 H HT Minimum required flow rate 25 l/min on E models; 22 l/min on E7 models
Altherma 3 H MT Minimum required flow rate 20 l/min
Altherma 3 H monobloc Minimum required flow rate 20 l/min
Altherma 3 M Heating 6 l/min
Altherma 3 M Cooling 10 l/min
Altherma 3 M Heating defrost 12 l/min
Altherma 3 M Backup heater (BUH) operation 12 l/min
Altherma 3 M Domestic hot water (DHW) 25 l/min
LT second-generation split Heat pump operation 6 l/min (04/08) or 10 l/min (11/16)
LT second-generation split Defrost 12 l/min (04/08) or 15 l/min (11/16)
LT second-generation split Backup heater operation 12 l/min (all models in that table)

The short family names in the table refer to these models and manuals:

  • Altherma 3 R — ERGA04–08E + EHBH/X04+08E, 4P629085-1E (2024.04)
  • Altherma 3 H HT — EPRA14–18D + ETBH/X16E, 4P644736-1D (2023.10)
  • Altherma 3 H MT — EPRA08–12E + ETBH/X12E, 4P634885-1 (2021.03)
  • Altherma 3 H monobloc — EPGA / EABH/X, 4P556070-1 (2018.10)
  • Altherma 3 M — EBLA/EDLA 04–08 Eâ–²V3 and Eâ–²3V3, 4P685228-1B (2023.05)
  • LT second-generation split — ERLQ + EHBH, 4P449969-1 (2016.06)

Safe owner checks

  • Pressure above 1 bar (maximum 3 bar).
  • Radiator valves, TRVs and zone valves open. Lots of closed TRVs leave little water for defrost.
  • No isolation valves closed.
  • Listen for gurgling (air). Bleed radiators only if confident.

Then reset at the interface. If it comes back, stop and call your installer.

What your engineer will check

Daikin’s order: closed valves, air, low flow or pressure, a missing bypass, a dirty magnetic filter, the flow sensor, the 3-way valve, the pump and the hydro PCB. On 3 H HT units the higher minimum flow makes 7H errors more likely when zones close.

FAQ

Why only in cold weather?

That’s when defrosts happen. A system that’s fine in heating can fall short during defrost.

Is it linked to 89 errors?

They can appear together: 89-03 is a freeze-up warning during defrost, also connected to low water temperature and flow.

Can I stop it recurring?

Keep valves open, pressure topped up and the magnetic filter cleaned at each annual service.

What to tell your engineer

A few details make diagnosis faster and can save a second visit:

  • Your outdoor and indoor model codes from the rating labels.
  • The full code (for example XX-YY), with a photo of the help text and the malfunction history.
  • When it happened and what the system was doing: heating, hot water, defrost or starting up.
  • The pressure gauge reading, and whether any valves or radiators were recently touched.
  • Whether the code cleared on its own, came back after a reset, or appeared alongside other codes.
  • Any recent power cuts, storms or very cold, damp weather.

Manuals for figures on this page

These manuals support the figures named below. They are not a substitute for the book that matches the model on your rating plate, and they do not cover every sentence on this page.

Related guides

Safety first

Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer (F-gas certified for refrigerant work, and R290-competent for Altherma 4).

Still stuck?

Ask the Heat Pump Assistant with your model code and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.