Daikin Altherma Error Codes: What Each One Means

Last reviewed: November 2026. Help for Daikin Altherma owners.

Short answer

A Daikin Altherma error code is a short letter and number code followed by a sub-code, such as U4-00 or 7H-01. It tells you which part of the system has spotted a problem. Some codes clear themselves once the problem passes. Others stop the heat pump until a qualified engineer finds the cause, so use the table below to see which is which.

Illustration of a heat pump controller screen showing an error code warning
An error code on the controller is the first clue to what your heat pump needs.

How Daikin Altherma error codes work

When the heat pump detects something outside its normal limits it shows a code on the user interface. This is the controller on the indoor unit or on the wall. The code points to the area of the system involved. It does not always tell you exactly which part has failed.

Main code and sub-code

Most codes on Altherma 3 models have two parts. The first part, such as 7H, shows the area of the fault. The second part, such as 01, adds detail. So 7H-01 and 7H-05 are both water flow problems, but they appear in different situations.

Diagram explaining a heat pump error code split into main code and sub-code
The main code shows the area of the fault. The sub-code narrows it down.

Codes can differ between models

The meanings below come from Daikin service documents for Altherma 3 models. Older Altherma models, the Hybrid and Altherma 4 can use different codes or sub-codes. Always check the error list in the manual for your exact model. The model number is on the label of the indoor and outdoor units. Our guide to finding the right Daikin Altherma manual explains how.

Common Daikin Altherma error codes

Use this table to see what a code means and who should deal with it. “Owner check first” means there are simple, safe checks you can do before you call someone. “Engineer” means the fix involves parts, wiring or refrigerant.

Water, hot water and indoor unit codes

CodeWhat it meansWho should deal with it
7H-01, 7H-04, 7H-05, 7H-06Water flow problemOwner check first, then engineer
7H-07Pump de-blocking routine activeUsually clears itself. Engineer if it repeats
AH-00Tank disinfection (legionella cycle) not completedOwner check first, then installer
C0-00, C0-01, C0-02Flow detected when the pump is off, or flow switch problemEngineer
89-01 to 89-03Heat exchanger freezing protectionEngineer
8H-00, 8H-03Water circuit temperature too highEngineer
80-00, 81-00Return or leaving water temperature sensor faultEngineer
AA-01, AC-00Backup heater or booster heater overheatedEngineer
AJ-03Hot water took too long to heat upOwner check first, then engineer
EC-00, EC-04Abnormal tank temperature rise or tank preheatingEngineer if it keeps coming back
HJ-10Water pressure sensor abnormalityOwner check first, then engineer
U3-00Underfloor screed dry-out not completedInstaller

Communication codes

CodeWhat it meansWho should deal with it
U4-00Indoor and outdoor units cannot communicateOwner check first, then engineer
U5-00User interface communication problemOwner check first, then engineer
U7-00Communication problem inside the outdoor unitEngineer
U8-01 to U8-03Lost connection to the LAN adapter or room thermostatOwner check first, then installer

Outdoor unit and refrigerant codes

CodeWhat it meansWho should deal with it
A5-00High pressure peak cut or freeze protectionOwner check of the outdoor unit, then F-Gas engineer
U0-00Refrigerant shortage detectedF-Gas engineer only
E3-00High pressure switch trippedF-Gas engineer
E5-00Compressor overheat or start problemF-Gas engineer
E7-00Outdoor fan motor problemOwner check for ice or debris, then engineer
F3-00Discharge pipe temperature problemF-Gas engineer
U2-00Power supply voltage problemElectrician or engineer
L4-00Inverter fin temperature riseOwner check that the outdoor unit is clear, then engineer

Older Altherma HT codes (EKHBRD with ERRQ or ERSQ)

The first-generation Altherma HT uses two-character codes without a sub-code. These are the ones owners ask about most. Check the error list in the installation manual for your EKHBRD indoor unit.

CodeWhat it meansWho should deal with it
A6Pump error in the water circuit, or another water system errorOwner check first, then engineer
AEWater circuit error (blocked flow, 3-way valve position or a circuit the pump cannot push water around)Owner check first, then engineer

Please note: this list covers the codes owners ask about most. It is not complete. If your code is not here, check your manual or ask the chat assistant above.

What you can safely check yourself

Checklist graphic of safe checks a heat pump owner can do before calling an engineer
Only do the checks on this list. Leave everything inside the casing to an engineer.
  1. Write down the full code, the date, the time and what the system was doing. An engineer will ask for all of this.
  2. Read the water pressure on the controller or gauge. Compare it with the range in your manual. See our guide to Daikin Altherma water pressure.
  3. Check radiators and zone valves have not been turned off. Many flow codes start with a closed valve.
  4. Look at the outdoor unit from the outside only. Clear leaves, snow or anything blocking the grille by hand. Never chip ice off the fins or use hot water on them.
  5. Check your consumer unit. If a breaker for the heat pump has tripped and trips again, leave it off and call an electrician or engineer.
  6. Reset once only, following your user guide. If the code comes back, stop. Our guide on how to reset a Daikin Altherma error code explains when a reset is sensible.

What you should never do

  • Do not remove panels or open the indoor or outdoor unit. There are live parts inside, even when the controller is off.
  • Do not touch wiring, circuit boards or refrigerant pipes. Refrigerant work by law needs an F-Gas qualified engineer.
  • Do not try to get into installer settings menus. Wrong settings can damage the system or affect your warranty.
  • Do not keep resetting a code that returns. Some faults, such as low refrigerant, can damage the compressor if the unit keeps running.

When to call an engineer

Call a qualified heat pump engineer if:

  • the code returns after one reset
  • the code relates to refrigerant, pressure switches, the compressor or circuit boards
  • a breaker trips more than once
  • you see water leaking, smell burning or hear grinding from either unit
  • your home is without heating or hot water in cold weather

Have your model number, the full code and your notes ready. If your system is under warranty, contact your installer first.

Book a heat pump engineer

FAQs

Where do I see the error code on my Daikin Altherma?

The code shows on the user interface, which is the controller on the indoor unit or on the wall. Depending on your setup it may also appear in the Onecta app. Write down the full code including the sub-code.

Can I reset a Daikin Altherma error code myself?

You can usually try one reset by following your user guide. If the code comes back, do not keep resetting it. Repeated resets can hide a real fault and some faults can damage the heat pump.

Are the error codes the same on every Daikin Altherma?

No. The common codes are similar across Altherma 3 models, but older models, the Hybrid and Altherma 4 can differ. Always check the error list in the manual for your model number.

Is it safe to keep using my heat pump with an error code?

It depends on the code. AH-00, for example, does not stop the heat pump and often clears itself. Codes about refrigerant, pressure or electrics need an engineer before you keep using the system.

What does U4-00 mean on a Daikin Altherma?

U4-00 means the indoor and outdoor units have lost communication. It often appears after a power cut. If a full restart does not clear it, call an engineer.

Sources we checked

These manuals support the figures named below. They are not a substitute for the book that matches the model on your rating plate, and they do not cover every sentence on this page.

This is general guidance only. For faults or anything electrical, please contact a qualified heat pump engineer or Daikin directly.

Ask My Heat Pump is an independent support site. We are not affiliated with, endorsed by or sponsored by Daikin.