Last reviewed: November 2026. Help for Daikin Altherma owners.
Short answer
A Daikin Altherma error code is a short letter and number code followed by a sub-code, such as U4-00 or 7H-01. It tells you which part of the system has spotted a problem. Some codes clear themselves once the problem passes. Others stop the heat pump until a qualified engineer finds the cause, so use the table below to see which is which.
How Daikin Altherma error codes work
When the heat pump detects something outside its normal limits it shows a code on the user interface. This is the controller on the indoor unit or on the wall. The code points to the area of the system involved. It does not always tell you exactly which part has failed.
Main code and sub-code
Most codes on Altherma 3 models have two parts. The first part, such as 7H, shows the area of the fault. The second part, such as 01, adds detail. So 7H-01 and 7H-05 are both water flow problems, but they appear in different situations.
Codes can differ between models
The meanings below come from Daikin service documents for Altherma 3 models. Older Altherma models, the Hybrid and Altherma 4 can use different codes or sub-codes. Always check the error list in the manual for your exact model. The model number is on the label of the indoor and outdoor units. Our guide to finding the right Daikin Altherma manual explains how.
Common Daikin Altherma error codes
Use this table to see what a code means and who should deal with it. “Owner check first” means there are simple, safe checks you can do before you call someone. “Engineer” means the fix involves parts, wiring or refrigerant.
Water, hot water and indoor unit codes
| Code | What it means | Who should deal with it |
|---|---|---|
| 7H-01, 7H-04, 7H-05, 7H-06 | Water flow problem | Owner check first, then engineer |
| 7H-07 | Pump de-blocking routine active | Usually clears itself. Engineer if it repeats |
| AH-00 | Tank disinfection (legionella cycle) not completed | Owner check first, then installer |
| C0-00, C0-01, C0-02 | Flow detected when the pump is off, or flow switch problem | Engineer |
| 89-01 to 89-03 | Heat exchanger freezing protection | Engineer |
| 8H-00, 8H-03 | Water circuit temperature too high | Engineer |
| 80-00, 81-00 | Return or leaving water temperature sensor fault | Engineer |
| AA-01, AC-00 | Backup heater or booster heater overheated | Engineer |
| AJ-03 | Hot water took too long to heat up | Owner check first, then engineer |
| EC-00, EC-04 | Abnormal tank temperature rise or tank preheating | Engineer if it keeps coming back |
| HJ-10 | Water pressure sensor abnormality | Owner check first, then engineer |
| U3-00 | Underfloor screed dry-out not completed | Installer |
Communication codes
| Code | What it means | Who should deal with it |
|---|---|---|
| U4-00 | Indoor and outdoor units cannot communicate | Owner check first, then engineer |
| U5-00 | User interface communication problem | Owner check first, then engineer |
| U7-00 | Communication problem inside the outdoor unit | Engineer |
| U8-01 to U8-03 | Lost connection to the LAN adapter or room thermostat | Owner check first, then installer |
Outdoor unit and refrigerant codes
| Code | What it means | Who should deal with it |
|---|---|---|
| A5-00 | High pressure peak cut or freeze protection | Owner check of the outdoor unit, then F-Gas engineer |
| U0-00 | Refrigerant shortage detected | F-Gas engineer only |
| E3-00 | High pressure switch tripped | F-Gas engineer |
| E5-00 | Compressor overheat or start problem | F-Gas engineer |
| E7-00 | Outdoor fan motor problem | Owner check for ice or debris, then engineer |
| F3-00 | Discharge pipe temperature problem | F-Gas engineer |
| U2-00 | Power supply voltage problem | Electrician or engineer |
| L4-00 | Inverter fin temperature rise | Owner check that the outdoor unit is clear, then engineer |
Older Altherma HT codes (EKHBRD with ERRQ or ERSQ)
The first-generation Altherma HT uses two-character codes without a sub-code. These are the ones owners ask about most. Check the error list in the installation manual for your EKHBRD indoor unit.
| Code | What it means | Who should deal with it |
|---|---|---|
| A6 | Pump error in the water circuit, or another water system error | Owner check first, then engineer |
| AE | Water circuit error (blocked flow, 3-way valve position or a circuit the pump cannot push water around) | Owner check first, then engineer |
Please note: this list covers the codes owners ask about most. It is not complete. If your code is not here, check your manual or ask the chat assistant above.
What you can safely check yourself
- Write down the full code, the date, the time and what the system was doing. An engineer will ask for all of this.
- Read the water pressure on the controller or gauge. Compare it with the range in your manual. See our guide to Daikin Altherma water pressure.
- Check radiators and zone valves have not been turned off. Many flow codes start with a closed valve.
- Look at the outdoor unit from the outside only. Clear leaves, snow or anything blocking the grille by hand. Never chip ice off the fins or use hot water on them.
- Check your consumer unit. If a breaker for the heat pump has tripped and trips again, leave it off and call an electrician or engineer.
- Reset once only, following your user guide. If the code comes back, stop. Our guide on how to reset a Daikin Altherma error code explains when a reset is sensible.
What you should never do
- Do not remove panels or open the indoor or outdoor unit. There are live parts inside, even when the controller is off.
- Do not touch wiring, circuit boards or refrigerant pipes. Refrigerant work by law needs an F-Gas qualified engineer.
- Do not try to get into installer settings menus. Wrong settings can damage the system or affect your warranty.
- Do not keep resetting a code that returns. Some faults, such as low refrigerant, can damage the compressor if the unit keeps running.
When to call an engineer
Call a qualified heat pump engineer if:
- the code returns after one reset
- the code relates to refrigerant, pressure switches, the compressor or circuit boards
- a breaker trips more than once
- you see water leaking, smell burning or hear grinding from either unit
- your home is without heating or hot water in cold weather
Have your model number, the full code and your notes ready. If your system is under warranty, contact your installer first.
FAQs
Where do I see the error code on my Daikin Altherma?
The code shows on the user interface, which is the controller on the indoor unit or on the wall. Depending on your setup it may also appear in the Onecta app. Write down the full code including the sub-code.
Can I reset a Daikin Altherma error code myself?
You can usually try one reset by following your user guide. If the code comes back, do not keep resetting it. Repeated resets can hide a real fault and some faults can damage the heat pump.
Are the error codes the same on every Daikin Altherma?
No. The common codes are similar across Altherma 3 models, but older models, the Hybrid and Altherma 4 can differ. Always check the error list in the manual for your model number.
Is it safe to keep using my heat pump with an error code?
It depends on the code. AH-00, for example, does not stop the heat pump and often clears itself. Codes about refrigerant, pressure or electrics need an engineer before you keep using the system.
What does U4-00 mean on a Daikin Altherma?
U4-00 means the indoor and outdoor units have lost communication. It often appears after a power cut. If a full restart does not clear it, call an engineer.