A5-00 sits in Daikin’s refrigerant and compressor group of codes. It’s a protection, not a setting you can change, and it needs an engineer if it persists. Here’s what Daikin’s documents say.
What A5 means
- Altherma 3 (A5-00): high pressure peak cut / freeze protection.
- First-generation LT (“A5”): refrigerant temperature.
- Altherma 3 H (EPGA): same meaning as other Altherma 3 models.
Either way, the unit has spotted refrigerant conditions outside safe limits and protected itself.
Why it can happen
Daikin doesn’t publish an owner-level cause list for A5-00, so we won’t guess. What we do know is that many refrigerant-side protections are more likely when the water side isn’t moving heat properly, for example low flow or low pressure, and when the outdoor coil is blocked. That’s why the owner checks below focus on those.
Safe owner checks
- Check the outdoor unit from outside: clear of snow, ice build-up, leaves or anything blocking the fan or coil.
- Check the pressure gauge reads above 1 bar.
- Make sure radiator valves, TRVs and zone valves are open.
- Photograph the code, help text and the [8.2] malfunction history.
- Don’t open the unit, and don’t keep resetting it.
What your engineer will do
A5-00 needs an F-gas certified engineer. They’ll read the history, check flow and the refrigerant circuit, and look at sensors. If the code came alongside 89 freeze-up warnings or a 7H flow code, mention it, as it helps narrow things down.
FAQ
Is A5 dangerous?
It’s a protection doing its job. The unit stops to avoid damage. It still needs investigating.
Can I reset A5-00?
Daikin’s advice is to find the cause first. If it returns after a reset, stop and call an engineer.
Could it be the weather?
Ice or snow blocking the outdoor unit can contribute. Clear it gently from outside only; never chip ice or pour boiling water over the coil.
What to tell your engineer
A few details make diagnosis faster and can save a second visit:
- Your outdoor and indoor model codes from the rating labels.
- The full code (for example XX-YY), with a photo of the help text and the malfunction history.
- When it happened and what the system was doing: heating, hot water, defrost or starting up.
- The pressure gauge reading, and whether any valves or radiators were recently touched.
- Whether the code cleared on its own, came back after a reset, or appeared alongside other codes.
- Any recent power cuts, storms or very cold, damp weather.
Related guides
Safety first
Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer (F-gas certified for refrigerant work, and R290-competent for Altherma 4).
Still stuck?
Ask the Heat Pump Assistant with your model code and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.