Grant Aerona Error Codes: Aerona³ R32 and Aerona 290

Grant’s two current air source ranges use different error codes, so check your model first. The Aerona³ R32 (HPID6R32, HPID10R32, HPID13R32, HPID17R32) and the Aerona 290 (HPR2904 to HPR290155, R290 refrigerant) each have their own manual and code list.

Aerona³ R32: how codes show

A red LED flashes on the remote controller’s ON/OFF switch, and a warning icon and code appear on the LCD and the terminal PCB display. Many codes reset automatically once conditions return to normal. Grant describes a manual reset by holding – and + on the remote for three seconds. It advises against resetting by switching the mains off and on.

Aerona³ codes owners can act on

  • FU (high-pressure switch): Grant lists air recirculation, a clogged water circuit or a large flow–return temperature difference (low flow). Check the outdoor unit is clear and the system pressure is normal.
  • P1 (pump error): needs an engineer.
  • E8 / F5 (communication): needs an engineer.
  • A0, A3, C5, C6, C8, L0: electrical, PCB or EEPROM faults for an engineer. Several A, C, E and L codes are sensor faults checked with a meter.

Aerona 290: codes owners can act on

  • P01 (water flow): circulating flow below 8.3 L/min, or the flow switch below 4.6 L/min. Grant lists lack of water, a faulty flow switch, a blocked filter or air as causes. It says P01 is common at commissioning because of trapped air.
  • P02 (high pressure): Grant first points to low water flow. Check system pressure.
  • P04 (condenser): Grant points to outdoor fan airflow. Clean leaves or debris from the grille.
  • P03, P05, P14: point to refrigerant problems, for an engineer only.
  • E02–E36: sensor, communication and inverter faults.

Grant notes that in cold conditions the compressor may take up to 30 minutes to start. A delay alone is not a fault.

FAQ

My Aerona³ shows FU on a cold morning. What should I check?

Clear snow or leaves from the unit, then check the pressure gauge. If FU returns, call your installer: low flow is a common cause.

Can I reset an Aerona 290 fault myself?

Grant describes power cycling through the Smart controller. If the code comes back, stop and call your installer.

What to tell your engineer

  • Model (HPID…R32 or HPR290…) and serial number.
  • The exact code and a photo of the display.
  • The system pressure reading.
  • When it happened: heating, hot water, defrost or start-up.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Grant Aerona³ R32 installation instructions DOC 0136 Rev 2.4 (Feb 2024): p53–57 (printed = PDF); p11 (printed = PDF). Official PDF
  • Grant Aerona 290 installation instructions DOC 0204 Rev 1.9 (Aug 2026): p5 and p54–57 (printed = PDF). Official PDF

Related guides

Safety first

Owners can check pressure, controls and the outdoor grille. Electrical, internal and refrigerant work is for a qualified engineer, and the Aerona 290 uses flammable R290, so it needs an engineer competent with it.

Still stuck?

Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.

Independent guide, not affiliated with or endorsed by Grant.