Grant’s two current air source ranges use different error codes, so check your model first. The Aerona³ R32 (HPID6R32, HPID10R32, HPID13R32, HPID17R32) and the Aerona 290 (HPR2904 to HPR290155, R290 refrigerant) each have their own manual and code list.
Aerona³ R32: how codes show
A red LED flashes on the remote controller’s ON/OFF switch, and a warning icon and code appear on the LCD and the terminal PCB display. Many codes reset automatically once conditions return to normal. Grant describes a manual reset by holding – and + on the remote for three seconds. It advises against resetting by switching the mains off and on.
Aerona³ codes owners can act on
- FU (high-pressure switch): Grant lists air recirculation, a clogged water circuit or a large flow–return temperature difference (low flow). Check the outdoor unit is clear and the system pressure is normal.
- P1 (pump error): needs an engineer.
- E8 / F5 (communication): needs an engineer.
- A0, A3, C5, C6, C8, L0: electrical, PCB or EEPROM faults for an engineer. Several A, C, E and L codes are sensor faults checked with a meter.
Aerona 290: codes owners can act on
- P01 (water flow): circulating flow below 8.3 L/min, or the flow switch below 4.6 L/min. Grant lists lack of water, a faulty flow switch, a blocked filter or air as causes. It says P01 is common at commissioning because of trapped air.
- P02 (high pressure): Grant first points to low water flow. Check system pressure.
- P04 (condenser): Grant points to outdoor fan airflow. Clean leaves or debris from the grille.
- P03, P05, P14: point to refrigerant problems, for an engineer only.
- E02–E36: sensor, communication and inverter faults.
Grant notes that in cold conditions the compressor may take up to 30 minutes to start. A delay alone is not a fault.
FAQ
My Aerona³ shows FU on a cold morning. What should I check?
Clear snow or leaves from the unit, then check the pressure gauge. If FU returns, call your installer: low flow is a common cause.
Can I reset an Aerona 290 fault myself?
Grant describes power cycling through the Smart controller. If the code comes back, stop and call your installer.
What to tell your engineer
- Model (HPID…R32 or HPR290…) and serial number.
- The exact code and a photo of the display.
- The system pressure reading.
- When it happened: heating, hot water, defrost or start-up.
Manual references
Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.
- Grant Aerona³ R32 installation instructions DOC 0136 Rev 2.4 (Feb 2024): p53–57 (printed = PDF); p11 (printed = PDF). Official PDF
- Grant Aerona 290 installation instructions DOC 0204 Rev 1.9 (Aug 2026): p5 and p54–57 (printed = PDF). Official PDF
Related guides
- Grant Aerona Low Flow: Minimum Flow and Fixes
- Grant Aerona Servicing: UK Owner Guide
- Grant Aerona Controls: Remote, Programmer and Smart
Safety first
Owners can check pressure, controls and the outdoor grille. Electrical, internal and refrigerant work is for a qualified engineer, and the Aerona 290 uses flammable R290, so it needs an engineer competent with it.