Last reviewed: November 2026. Help for heat pump owners in the UK.
Short answer
Colder weather, a heating curve that is set too high, large on-and-off swings, a backup or boost heater that is coming on too often, or a legionella cycle that is running more frequently than you need can all raise electricity use. Energy Saving Trust and Daikin both favour steady running and a lower flow or leaving water temperature where the system still keeps you comfortable. This page does not invent a typical kWh or a saving in pounds. Use your own meter readings and the brand running-cost guides, and deal with fault codes promptly.
First, compare use with the weather
A heat pump uses more electricity as the outdoor temperature falls, because it has more work to do and because defrost cycles are more frequent in cold, damp weather. A jump in kWh between October and January is not proof of a fault on its own. Compare similar weather. Use your meter or the official app rather than a round figure from a forum.
This page does not invent a typical daily kWh or a saving in pounds. Brand-specific running-cost pages on this site, starting with Why is my Daikin Altherma using so much electricity?, follow the same rule.
Efficiency tips from official sources
Energy Saving Trust’s guide to running a heat pump efficiently recommends:
- Checking that the heating curve, also called weather compensation, is not set higher than you need.
- Leaving the heat pump on for extended periods, with a setback rather than switching it off and on like a boiler.
- Lowering the flow temperature in small steps if the house still stays comfortable.
- Checking that a legionella or sterilisation cycle is not running more often than your household needs, because that function heats the cylinder to a higher temperature.
- Making sure a heating boost or backup heater is set to come on only when the outdoor temperature is low enough.
- Dealing with fault messages promptly, rather than leaving a warning on the screen.
Daikin’s Altherma 3 user reference guides add: use a weekly schedule, do not raise the room temperature to try to heat faster, avoid large swings especially with slow emitters, and do not set the tank hotter than you need. Daikin states that each saved degree can save up to 6% of heating or cooling costs. That tip applies to the Altherma 3 manuals we checked, not automatically to every brand.
What you can check yourself
- Look for a backup, boost or immersion event in the app or on the controller, and see how long it is running. For Daikin, see backup heater and high bills. For Vaillant, see Vaillant backup heater.
- Write down any error code and use the brand error-code guide.
- Keep a modest, steady schedule. See should I leave my heat pump on all the time?.
- Book the yearly service in the servicing guide if it is overdue.
If you want help reading a setting or a chart in the official app, use the chat on this page or start at heat pump help.
Use the chat above to ask a question about your heat pump. We do not pass your details on to installers.
FAQs
How do I know if my use is actually high?
Compare your daily or weekly kWh with similar outdoor temperatures, not with a mild week or with an old gas bill in isolation. Use rises in cold weather are expected. This page does not publish a typical kWh or a pound figure, because that depends on the house, the tariff and the weather.
What do official guides say can raise use?
Energy Saving Trust points to a heating curve that is set too high, short on-and-off running, a legionella or sterilisation cycle that is set more often than needed, and a boost or backup heater that is coming on too readily. Daikin’s tips include a weekly schedule, avoiding large room-temperature swings and not setting water hotter than you need. Each saved degree can save up to 6% of heating or cooling costs on Altherma 3, according to Daikin, which is a manufacturer tip rather than a guarantee.
Should I switch the heat pump off to save electricity?
Usually not. Energy Saving Trust says heat pumps work best when left running all day with a setback, and that leaving them on for longer can be more efficient than a boiler-style on-and-off pattern. See should I leave my heat pump on all the time?.
When should I call an engineer?
If a backup or boost heater seems to be on much of the time, if fault codes keep appearing, if rooms will not heat without turning everything up, or if use has jumped without a change in the weather. Deal with warnings promptly, as Energy Saving Trust advises. Yearly servicing is covered in the servicing guide.