We don’t quote prices, because tariffs change. Mitsubishi Heavy Industries’ Hydrolution manuals do explain what drives energy use. This guide covers Hydrolution (HM) systems with RC-HY20-W/RC-HY40-W controllers, using MHI’s user’s manual PSB012A016B and installation manual PSC012D169A.
What MHI says affects consumption
- Indoor temperature, hot water use, insulation, large windows, and the house’s position, such as wind exposure.
- Each extra degree of indoor temperature raises power consumption by about 5%, according to MHI.
Hot water choices
- MHI says “Hot water Economy” uses less energy.
- Luxury mode runs the immersion heater as well as the compressor, which may increase operating costs. Use temporary lux for occasional busy days instead.
- Smart control learns last week’s use and adapts the tank temperature to minimise energy.
Keep flow temperatures moderate
- MHI’s installation manual recommends no more than 55°C supply and 45°C return at the lowest design outdoor temperature.
- Get the heating curve right. Small offset changes are better than a permanently steep curve.
- Open TRVs in most rooms, so the heat pump isn’t fighting closed valves.
Avoid unnecessary electric addition
- Aid mode and “add. heat only” use electric addition, so use them only while waiting for a repair.
- MHI notes a minimum time between compressor starts. If it doesn’t start, wait 30 minutes before worrying.
- Holiday mode (menu 4.7) lowers demand while you’re away. Remember to switch it off on return.
Track it
MHI recommends checking your home’s energy meter regularly, preferably monthly, to spot changes in consumption.
FAQ
Is 21°C much more expensive than 20°C?
MHI’s rule of thumb is about 5% more power per degree.
Should I use luxury hot water all the time?
Not if you want lower bills. It brings in the immersion heater. Normal or smart control suits most homes.
Manual references
Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.
- Mitsubishi Heavy Industries Hydrolution (HM) user’s manual PSB012A016B (2024-08): EN-12 (PDF p14); EN-21 (PDF p23); EN-36–37 (PDF p38–39). Official PDF
- Mitsubishi Heavy Industries Hydrolution (HM) installation manual PSC012D169A: printed p23 (PDF p25). Official PDF
Related guides
- MHI Hydrolution Heating Curve and Weather Compensation
- MHI Hydrolution Hot Water: Comfort Modes and Lux
- MHI Hydrolution Servicing: UK Owner Guide
Safety first
Owners can use the RC-HY controller, read alarms and keep the units clear. Electrical, refrigerant (R32/R410A) and internal work is for a qualified engineer, so contact your dealer or installer.
Still stuck?
Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.