Octopus Cosy Maintenance: Pressure, Radiators and Cleaning

Octopus’s Cosy user manual lists a few simple jobs owners can do to keep the system efficient. Everything behind a cover is for an engineer.

Pressure and radiators

  • Pressure: top up with the filling loop to 1–1.5 bar when the system is cold.
  • Bleeding radiators: start downstairs at the radiator furthest from the cylinder, then do upstairs. Check the pressure afterwards.
  • TRVs: keep them open.

Clearances

As a rule of thumb, keep 1.5 m clear in front of and above the outdoor unit. The minimums are 500 mm on each side, 750 mm in front of the fan and 250 mm at the rear.

Cleaning the outdoor unit

  • Brush the fan grille clear, and wipe moss off the casing with a damp cloth.
  • Brush the evaporator softly. Never use a hose, pressure washer, metal brush or your hands.
  • Never open the covers or the fan cap.
  • Keep the Hub and Pods away from heat and water, and clean them with a soft dry cloth.

Ice and puddles

Defrosting is normal and most common between 7 °C and −5 °C outside. If excess ice persists, contact your installer. For a leak or puddle, carefully clear any obvious blockage. If that doesn’t fix it, contact your installer and don’t try a repair yourself.

Servicing

Octopus’s Cosy Care plan includes an optional annual engineer visit. Octopus says the visit is not mandatory for the warranty. Check current prices and terms with Octopus.

FAQ

What pressure should my Cosy system be?

Octopus’s manual says 1–1.5 bar when the system is cold, topped up with the filling loop.

Can I hose down my Cosy outdoor unit?

No. Octopus says never use a hose or pressure washer. Brush the grille and evaporator softly instead.

What to tell Octopus aftercare

  • Your Cosy model and pressure reading.
  • Photos of the outdoor unit and any ice or water.
  • The Hub light colour.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Octopus Energy Cosy Series User Manual ver 26-2 (Nov 2026): filling loop p18, maintenance p36–39, defrost p14 and p39 (PDF pages). Official PDF
  • Octopus Energy Cosy Care plans page (retrieved 15 Nov 2026). Official page