If your Cosy Heat Pump is running but the house is not warm enough, Octopus’s manual suggests a short list of checks.
If nothing is running
Check both the indoor and outdoor units are switched on, the app is connecting, and the circuit breaker hasn’t tripped. If all of those are fine, contact your installer.
If it runs but the house is cool
- Primary Pod: the Cosy heats to the temperature measured by the primary Pod. Check which room it is in, that it isn’t near a window or door, and that the room has no TRV.
- Setpoints and warm-up time: check your schedule temperatures and allow enough time for the house to warm up.
- Hush Mode: it caps the compressor and fan at 60 %, which can limit heat output. Turn it off if you need more heat.
- Hot water: the Cosy heats either the home or the cylinder, never both at once, and hot water takes priority.
- Radiators: keep TRVs open, bleed any that are cold at the top, then check the pressure.
Flow temperature
The Cosy can run a fixed flow temperature or weather compensation. Octopus describes the flow setting as a maximum target, not instant heat. Changing installer settings is a job for your installer.
FAQ
Does Hush Mode reduce heating?
Yes, it can. Octopus says Hush Mode caps the compressor and fan at 60 %, so heat output is limited while it is on.
Why is one room cold but the app says it’s warm?
The Cosy heats to the primary Pod’s reading. If that room warms quickly, other rooms may fall short. Check the Pod’s location and radiator valves.
What to tell Octopus aftercare
- Your Cosy model and roughly when it was installed.
- Which room the primary Pod is in, and its target and actual temperature.
- Whether Hush Mode or Smart Heating is on.
- The Hub light colour and your system pressure reading.
Manual references
Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.
- Octopus Energy Cosy Series User Manual ver 26-2 (Nov 2026): system parts p16–19, flow temperature p9–13, Pods p23, Hush Mode p29, troubleshooting p40–42 (PDF pages). Official PDF
Related guides
- Octopus Cosy Hub and Pod Lights Explained
- Octopus Cosy Smart Heating and Schedules Explained
- Octopus Cosy Maintenance: Pressure, Radiators and Cleaning
Safety first
Owners can change setpoints, Pods, Hush Mode and radiator valves. Leave installer settings, electrics and refrigerant work to a qualified engineer. The Cosy uses flammable R290.
Still stuck?
Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.
Independent guide, not affiliated with or endorsed by Octopus Energy.