This guide covers the Cosy Heat Pump’s own controls. If you have another brand of heat pump on the Cosy Octopus tariff, see that brand’s guides instead.
What Smart Heating needs
- A Cosy 6, 9 or 12.
- A SMETS2 smart meter and an Octopus tariff.
- Heating and hot water both set to Schedule.
How it behaves
- It takes 12–36 hours to learn your home.
- The end of a hot water slot is treated as a “ready by” time, and the Cosy heats the water within the six hours before it.
- Pressing the mode buttons on the Hub can switch Smart Heating off. Look for the leaf icon to check it is still on.
- Smart Heating and Hush Mode can’t run at the same time.
A schedule without Smart Heating
Octopus’s current manual suggests these settings if you schedule around tariff periods yourself:
- Dip: 1–2 °C above your usual temperature.
- Standard: your usual 20–21 °C.
- Peak: 1–2 °C below your usual temperature.
The older 20.2 guide gave dip +1–3 °C and peak −2–3 °C. Follow the manual you were given.
FAQ
How long does Cosy Smart Heating take to learn?
Octopus says 12 to 36 hours.
Why did Smart Heating turn itself off?
Pressing the Hub mode buttons can switch it off, and it can’t run with Hush Mode. Check for the leaf icon.
What to tell Octopus aftercare
- Your Cosy model and tariff.
- Whether the leaf icon shows, and your heating and hot water modes.
- When Smart Heating was switched on.
Manual references
Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.
- Octopus Energy Cosy Series User Manual ver 26-2 (Nov 2026): tariff schedule p26, Hush Mode p29, Smart Heating p30–35 (PDF pages). Official PDF
- Octopus Energy Get to know your Cosy 20.2 (Feb 2025, Cosy 6 and Cosy 9 era): earlier schedule guidance. Official PDF
Related guides
- Octopus Cosy Hot Water Settings and Legionella
- Octopus Cosy Not Heating Enough: Owner Checks
- Octopus Cosy Hub and Pod Lights Explained
Safety first
Schedules and modes are safe for owners to change. Installer settings, behind the Hub’s installer access mode, are for your installer only.
Still stuck?
Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.
Independent guide, not affiliated with or endorsed by Octopus Energy.