Samsung EHS Tank Hydro Unit Hot Water Guide

Samsung’s Tank Integrated Hydro Unit combines the cylinder, pump and controls in one indoor unit. This guide covers the AE200/260RNWSEG and AE260RNWSGG split models and the AE200/260RNWMEG and AE260RNWMGG mono models, using Samsung manual DB68-08367A-07. It does not cover CNW-plate units.

How the unit heats hot water

  • The heat pump and booster heater work together until the initial set temperature is reached. After that, depending on the installer’s settings, only the booster heater may run.
  • The booster heater is 3 kW. There is also a 2 kW backup heater for space heating, or 6 kW on GG models.
  • Heat pump hot water runs at outdoor temperatures of −25°C to 35°C. The unit’s wider hot water range extends to 43°C.

The 55°C rule

Samsung’s instruction is clear: if you set the hot water supply temperature to 55°C or less, do not use the booster heater. Keeping the target at or below that level lets the heat pump do the work, which is normally the cheaper way to heat water.

Legionella and disinfection

A disinfection cycle that does not reach or hold its temperature shows code 919. Your installer sets the schedule and temperature. If you see 919, ask them to check it rather than raising settings yourself.

Safety valves on the hot water side

  • The relief valve discharge must be open to atmosphere through a tundish.
  • Samsung advises operating the relief valve regularly to remove lime deposits.
  • The pressure reducing valve and expansion relief are field-supplied, not Samsung parts.
  • Water from the tundish while heating is not normal. Isolate the unit and call your installer.

Two-zone systems

Where two heating zones are fitted, the installer enables two-zone control and the mixing valve in field settings. Hot water still comes from the same cylinder.

FAQ

Why is my hot water slow to recover?

A heat pump heats more gently than an immersion heater. Low settings or a big draw-off take longer to recover. That is normal unless the water never reaches temperature.

Should I turn the booster heater on for hotter water?

Only if you need above 55°C. Below that, Samsung says not to use it.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Samsung EHS Tank Integrated Hydro Unit installation manual DB68-08367A-07: p8 and p10 (printed ENGLISH-8/10 = PDF); p14 and p16 (printed = PDF); p54–56 (printed = PDF); p60–61 (printed = PDF). Official PDF
  • Samsung EHS R32 Mono outdoor unit installation manual DB68-11904A-05: p47 (printed = PDF). Official PDF

Related guides

Safety first

Owners can read codes, check the pressure gauge and valves, and keep the outdoor unit clear. Electrical, refrigerant (R32) and internal work, and any installer settings, are for a qualified, F-gas certified engineer.

Still stuck?

Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.