The sensoCOMFORT VRC 720 is the system control covered by Vaillant’s VRC 720/3 operating and installation instructions — the usual controller with the aroTHERM plus /6.
Getting around
- Press the home/back button once for the basic display, twice for the menu.
- The main menu has three parts: MENU | CONTROL, MENU | INFORMATION and MENU | SETTINGS.
- The basic display shows symbols for noise reduction, Green iQ and the spanner for faults or maintenance.
Heating modes
In MENU | CONTROL | Zone | Heating | Mode:
- Manual: holds the desired temperature all the time.
- Time-contr.: a weekly planner with up to 12 time periods a day. Outside them it uses the set-back temperature, or switches off, depending on how your installer set it up.
- Off: heating off with frost protection on. Hot water still works.
Hot water
- DHW presetting Comfort or Eco (factory Comfort). Eco reheats to the Reduced DHW temperature after a big draw-off. The Reduced DHW temperature factory setting is 49 °C.
- Mode Manual, Time-contr. (up to 3 periods a day) or Off, plus the DHW temperature.
- Hot water boost heats the cylinder once, now.
Absence and temporary changes
- Absence: set from and to dates. Heating drops to the set-back temperature (factory 15 °C), hot water is off and the anti-legionella cycle is skipped.
- There’s no quick override key. Switch Mode to Manual for a while and back to Time-contr. later, or use the timed override in the myVAILLANT app.
- Time programme assistant sets Monday to Friday and the weekend in one go (it overwrites your weekly planners).
Useful information screens
MENU | INFORMATION shows current room and cylinder temperatures, water pressure, energy data (estimates only), your installer’s contact details and the serial number.
Settings to leave alone
- Installer level is code-protected. We can’t provide installer codes.
- Never use Factory settings. It wipes your installer’s set-up.
- Language rescue: press home twice, choose the last item (SETTINGS), then the second item, then your language.
Common fixes
- Display dark or frozen: hold the top-right button for over 5 seconds to restart it. If it’s still stuck, switch the heat pump off at its isolator for about a minute and back on.
- Button lock: press the top-right button for about 1 second.
- “Mode: Back-up heater if fault occurs”: the heat pump has failed and limp-home is active. You can choose Off, Heating, DHW or both for the back-up until the engineer comes, but running on the back-up is expensive.
FAQ
Can I change the heat curve on the sensoCOMFORT?
The heat curve is an installer-level setting on the controller. Ask your installer to set it.
What does Green iQ mean?
It’s the most energy-efficient mode, where your system supports it.
Related guides
- Vaillant heat curve settings
- Room temp. mod. explained
- Hot water and legionella
- myVAILLANT app guide
Safety first
Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer. aroTHERM plus and aroTHERM pro units use R290, so refrigerant work needs an engineer competent with flammable refrigerants.
Still stuck?