Viessmann Vitocal Heating Curve: Slope and Level

On the Vitocal 150-A and 250-A with the 7-inch touchscreen, the heating curve sets the flow temperature from the outside temperature. It has two settings: Slope and Level. Factory settings depend on your system. Viessmann’s example shows a Slope of 1.4 and a Level of 0.

Where to find it

On the touchscreen, open “Room climate”, choose the heating/cooling circuit (for example “Heating/cooling circuit 1”), then “Heating curve”. Change Slope and Level, and confirm.

Viessmann’s tips

  • Too cold in winter: raise the Slope one step.
  • Too warm in winter: lower the Slope one step.
  • Too cold in spring, autumn and winter: raise the Level.
  • Too warm in spring, autumn and winter: lower the Level.
  • Too cold in spring/autumn but fine in winter: lower the Slope one step and raise the Level.
  • Too warm in spring/autumn but fine in winter: raise the Slope one step and lower the Level.

Change one step at a time and wait a day or so to judge the result.

Temporary changes

“Extend time phase once” keeps the last active temperature until the next time phase. “Holidays at home” heats as on your first time phase of the day, which is useful for days at home.

FAQ

My house is cold only when it’s freezing outside. What should I change?

Viessmann’s tip is to raise the Slope one step when the home is too cold in winter.

What is the default Vitocal heating curve?

Factory settings depend on your system. Viessmann’s example uses a Slope of 1.4 and a Level of 0.

What to tell your contractor

  • Your model and which heating circuit you changed.
  • The Slope and Level before and after.
  • Which rooms are too warm or cold, and at what outside temperatures.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Viessmann operating instructions 6249162 (7/2025), control unit for Vitocal 150-A and 250-A: setting the heating curve p38, temporary changes p38–39. Official PDF