This guide covers the Vitocal 150-A, 151-A, 250-A and 252-A families with the 7-inch colour touchscreen. Older Vitocal models with a Vitotronic 200 controller use different, two-character codes: see our Vitotronic 200 guide.
How faults show
The display shows “Fault”, and the Lightguide flashes even when the screen is off. Messages are sorted into Status, Warnings, Information and Faults under “Message lists”.
- Tap the fault symbol in the navigation area, then “Faults”.
- Tap ? to see information and tips for things you can check yourself.
- Write down the fault number and cause, for example F.160 “Communication error CAN bus”.
- Tell your contractor, then acknowledge the fault.
Viessmann warns: do not acknowledge fault messages several times in quick succession. If troubleshooting has to wait, the message reappears the next day at 7:00.
Messages owners often see
- F.74 / A.11 (system pressure too low): F.74 switches the heat pump off. Viessmann’s service steps start with topping up and venting, then checking for leaks and the expansion vessel. Check your pressure gauge and call your contractor.
- F.75 (no flow rate in the secondary circuit): causes include closed valves, a blocked filter, a faulty pump, air, or frozen water near the outdoor unit’s non-return valve. This is for your contractor.
- F.13 (outside temperature sensor lead break): a sensor or wiring fault for your contractor.
- F.160 (CAN bus communication error): communication between components. Note it and call your contractor.
- “Outdoor unit locked”: follow the on-screen steps once. Do not unlock it repeatedly in quick succession. If it keeps returning, call your contractor. Other heat sources (if fitted) take over heating and hot water.
FAQ
My Vitocal shows F.74. What should I check?
F.74 means system pressure is too low and the heat pump switches off. Check the pressure gauge and call your contractor to top up and find the cause.
Can I keep acknowledging a Vitocal fault?
No. Viessmann warns not to acknowledge faults several times in quick succession. Note the message and notify your contractor.
What to tell your contractor
- Your model (for example Vitocal 250-A) and serial number from the type plate.
- The exact message number and text, with a photo.
- Your system pressure reading.
- When it happened: heating, hot water, defrost or start-up.
Manual references
Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.
- Viessmann operating instructions 6249162 (7/2025), control unit for Vitocal 150-A and 250-A: checking fault messages p57–58, What to do if p64–67. Official PDF
- Viessmann service instructions 6199893 (01/2026), monoblock heat pumps incl. Vitocal 150-A/151-A/250-A/252-A: F.74 and F.75 p123, F.13 p121, A.11 p201 (printed = PDF). Official PDF
Related guides
- Viessmann Vitocal Heating Curve: Slope and Level
- Viessmann Vitocal Maintenance and Safety for Owners
- Viessmann Vitotronic 200 (WO1C) Heat Pump Fault Codes
Safety first
Owners can read messages, check the pressure gauge and change user settings. The outdoor unit contains flammable R290 refrigerant. Electrical, internal and refrigerant work is for a qualified contractor.
Still stuck?
Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.
Independent guide, not affiliated with or endorsed by Viessmann.