Daikin Altherma U4-00 Error: Causes and Safe Checks

Last reviewed: November 2026. Help for Daikin Altherma owners.

Short answer

U4-00 means the indoor unit and the outdoor unit of your Daikin Altherma have stopped talking to each other. It often appears after a power cut or when the outdoor unit has lost power. A full, safe restart of the system sometimes clears it. If it comes back, a qualified engineer needs to check the power supply, wiring and circuit boards.

Diagram of an indoor heat pump unit and outdoor unit with a broken communication link
U4-00 means the two halves of the system have lost contact.

What U4-00 means

A split Daikin Altherma has an indoor unit and an outdoor unit linked by a communication cable. A monobloc has its controls in the outdoor unit with the user interface inside. In both cases the parts send signals to each other all the time. Daikin’s service manuals describe U4-00 as an indoor and outdoor unit communication problem. In plain terms the system cannot confirm the other side is there.

While U4-00 is showing, expect the heat pump to stop heating. Whether any backup heating runs depends on how your installer set up the system, so treat that as uncertain for your home.

Common causes of U4-00

Causes listed in Daikin documents

  • Power supply problems, such as a power cut, a voltage drop or a supply outside the normal range.
  • The outdoor unit has no power, for example a tripped breaker or an isolator switched off.
  • Wiring between the units that is loose, damaged or wrongly connected.

Other causes owners and engineers report

On heat pump forums, owners and engineers also report U4 faults traced to a failed circuit board in the outdoor unit and, less often, a faulty outdoor fan motor. We have not confirmed these in Daikin’s own documents, so treat them as possible causes for an engineer to check, not a diagnosis.

Why U4-00 often appears after a power cut

If the power drops briefly, the indoor and outdoor units may not restart at the same moment. One side can come back and fail to find the other. This is why a full restart of both units is the first thing most engineers suggest. See our guide to a Daikin Altherma after a power cut for more.

Safe checks you can do

Outdoor electrical isolator switch next to a heat pump
Many outdoor units have an isolator switch nearby. Check it is on, but never open it up.
  1. Note the code and the time. Did it start during a storm, a power cut or after electrical work?
  2. Check the consumer unit. Look for a tripped breaker labelled for the heat pump. If you reset it and it trips again, leave it off and call an electrician or engineer.
  3. Check the outdoor isolator. Many installs have a switch on the wall near the outdoor unit. Make sure it has not been knocked off. Do not open it.
  4. Do a full restart. Switch the heat pump off at its breaker or breakers, including any separate supply for the indoor unit. Wait a few minutes, then switch back on and give it time to start up. Only use switches you would normally use. If you are not sure which ones they are, ask your installer.
  5. Check the controller after start-up. If U4-00 does not return, keep an eye on it for a day or two.

Safety: never remove covers, test terminals or touch the communication cable. Even with the controller off, parts inside can be live.

CodeWhat it points to
U4-00Indoor and outdoor units cannot communicate
U5-00User interface communication problem
U7-00Communication problem between processors inside the outdoor unit
U8-01 to U8-03Lost connection to the LAN adapter or room thermostat

For the full list, see our Daikin Altherma error codes guide.

When to call an engineer

Call a qualified heat pump engineer if:

  • U4-00 returns after a full restart
  • a breaker trips more than once
  • the outdoor unit shows no signs of life at all
  • the code started after building, garden or electrical work near the cable route

Tell the engineer your model number, when the code started and whether there was a power cut. If your system is under warranty, contact your installer first.

Book a heat pump engineer

FAQs

Can a power cut cause U4-00 on a Daikin Altherma?

Yes. Daikin lists power supply problems as a cause. U4-00 often shows after a power cut. A full restart of both units sometimes clears it. If it returns, call an engineer.

Will my heating work while U4-00 is showing?

Usually the heat pump cannot heat while the units are not communicating. Some systems may run a backup heater depending on how they were set up, so check with your installer.

Can I fix U4-00 myself?

You can safely check breakers, the outdoor isolator and try one full restart. Anything involving wiring, covers or circuit boards is a job for a qualified engineer.

Is U4-00 the same as U5 or U7?

No. U5 relates to the user interface and U7 to communication inside the outdoor unit. U8 relates to the LAN adapter or room thermostat.

Sources we checked

This is general guidance only. For faults or anything electrical, please contact a qualified heat pump engineer or Daikin directly.

Ask My Heat Pump is an independent support site. We are not affiliated with, endorsed by or sponsored by Daikin.