Daikin Altherma Not Working? First Steps to Take

If your Altherma has stopped, don’t panic. Most problems have a simple first check, and the controller usually tells you what’s wrong.

1. Is there power?

  • Is the controller screen on?
  • Has there been a power cut? See our power cut guide.
  • Check the isolator switches near the units are on.
  • Don’t open any electrical panels.

2. Read the error code

Altherma 3: [0] Malfunctioning shows help text, [8.2] history. Altherma 4: [11]. Hybrid/LT: [6] Information. First-generation: flashing code. Our error codes hub explains common ones.

3. Check the operation settings

On Altherma 3, [C] Operation switches heating and the tank on and off. Check holiday mode isn’t active ([7.3]).

4. Is it just warm outside?

Heating stops above the space heating off temperature [4-02]. In mild weather the unit may simply not need to run.

5. Check water pressure

Above 1 bar, below 3 bar.

6. Is it defrosting?

Steam, a whoosh and a pause in heating for 5–15 minutes in damp, cold weather is normal defrost.

7. App offline?

If only Onecta has stopped, your heating is probably fine; the unit runs on its own controller.

8. Outdoor unit

From outside, check it’s clear of snow, leaves and debris. Never chip ice.

When to call your installer

  • Any refrigerant, electrical or compressor code.
  • A code that returns after a reset.
  • Banging, metallic knocking or grinding noises.
  • Altherma 4 A0-02/A0-26: ventilate and call urgently.

Stopgaps

Use the immersion for hot water if you have one.

FAQ

Screen blank, no power?

Check isolators and your consumer unit; if a breaker keeps tripping, call an electrician or installer.

No code but no heat?

Check settings, heating-off temperature and pressure, then see our not heating guide.

How do I speed up help?

Have your model codes and error photos ready.

Related guides

Safety first

Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer (F-gas certified for refrigerant work, and R290-competent for Altherma 4).

Still stuck?

Ask the Heat Pump Assistant with your model code and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.