Annual Heat Pump Maintenance: What Owners Should Do

Last reviewed: November 2026. Help for heat pump owners in the UK.

Short answer

Annual heat pump maintenance has two parts. Between visits you keep the outdoor unit clear of leaves, snow and clutter, wipe the controller the way your manual describes, read the water pressure against your own manual and note any new code, drip or noise. Once a year a competent engineer services the system to the manufacturer’s instructions and leaves you a record. Daikin’s Altherma 3 user guide says the installer has to perform a yearly maintenance. Vaillant’s aroTHERM plus instructions tell owners never to carry out maintenance work or repairs on the product themselves.

Two lists comparing owner checks between visits with the yearly service carried out by a competent engineer
You keep the unit clear and watch for changes. A competent engineer does the yearly service.

Two parts: owner checks and the yearly service

Annual maintenance is not one big job. Most of the year it is a few minutes of looking and clearing that any owner can do from outside the casing. Once a year a competent engineer does the inspection and servicing that the manufacturer specifies, then records it.

MCS’s heat pump installation standard (MIS 3005-I, Issue 1.0) says maintenance checks should be carried out periodically in line with the manufacturer’s requirements. It also says your handover documents should include the checks you are expected to carry out yourself, how often to do them and what to do if you find a problem. Look in your handover pack first.

Owner checks between visits

The outdoor unit

  • Vaillant’s aroTHERM plus instructions ask owners to regularly remove branches and leaves gathered around the unit, leaves and dirt from the ventilation grille below it and snow from the air inlet and outlet grilles and around the unit.
  • Vaillant’s handover guide adds: check the heat pump particularly in autumn and winter, do not stack things such as a bike or garden furniture against or on top of it and keep the area around it free of clutter so air can flow freely down the back and sides.
  • Grant UK advises owners to check regularly that the air inlet grill and evaporator are free of leaves and debris.
  • Never chip ice off the unit or pour hot water on it. See heat pump iced up for what normal frost looks like.

If you have an R290 unit such as the aroTHERM plus, Vaillant’s instructions also describe a protective zone around the unit. Do not use sprays or other combustible gases there, do not add ignition sources such as sockets or lights and do not make building changes in that zone.

Four seasonal cards with simple owner checks for autumn, winter, spring and summer
An illustrative year of owner checks. Your own manual and warranty set the details.

The controller and indoor unit

Daikin’s Altherma 3 user guide says to keep the user interface clean with a soft damp cloth and not to use detergents. Vaillant asks for a damp cloth and a little solvent-free soap on the outdoor casing. Follow your own manual for the indoor parts. Do not open covers or panels.

Pressure, codes and notes

  • Read the system water pressure against your own manual. Daikin says to check regularly that it stays above 1 bar. Vaillant’s fault-code guidance uses a normal range of 1 to 1.5 bar.
  • Do not ignore warnings on the screen. Energy Saving Trust advises checking the fault log for repeat messages and asking the installer or manufacturer what is causing them.
  • Write down any new code, drip or noise with the date. The engineer can use that history at the yearly visit.
Example log table with columns for date, water pressure, any code shown and notes
A simple log makes the yearly visit quicker and gives the engineer a history.

What the yearly engineer visit is for

The yearly visit covers the parts owners must not touch. As one example, the maintenance table in Vaillant’s aroTHERM plus installation instructions lists these annual tasks:

  • checking the protective zone around the unit
  • cleaning the product
  • checking the evaporator, fan and condensate discharge
  • checking the refrigerant circuit and its tightness
  • checking the electrical connections and wires

Daikin UK’s servicing article describes a similar visit with refrigerant leak testing, coil and filter cleaning, electrical safety checks and a service report.

Daikin’s Altherma 3 user guide also notes that periodic inspections for refrigerant leaks may be required depending on the applicable legislation and to ask your installer about this.

The service checklist explains what a typical visit covers, how often to service a heat pump covers timing and warranty and annual servicing explains why the record matters.

What owners should not do

  • Do not carry out maintenance work or repairs on the heat pump itself. Vaillant’s instructions say this plainly and Grant UK says you cannot service your own heat pump.
  • Do not hose down or rinse the unit. Daikin warns against it and Vaillant tells engineers not to use a high-pressure cleaner or a direct jet of water.
  • Do not work on refrigerant, wiring or anything behind a cover.
  • Do not change installer settings to make up for a fault. Book the engineer.

Energy Saving Trust also points out that faulty pumps, valves or sludge in the radiators can look like a heat pump fault and that a system without water treatment and a filter can develop long-term problems. Ask about both at the yearly visit. Start at the heat pump servicing guide for the wider picture.

Use the chat above to ask a question about your heat pump. We do not pass your details on to installers.

FAQs

What maintenance does a heat pump need each year?

A yearly service by a competent engineer, done to the manufacturer’s instructions, plus simple owner checks in between. Daikin’s Altherma 3 user guide lists the owner part as keeping the area around the unit clean, cleaning the user interface with a soft damp cloth and checking regularly that the water pressure is above 1 bar. Vaillant and Grant UK both ask owners to keep the outdoor unit clear of leaves and debris and to have the heat pump serviced annually.

Can I clean the outdoor unit myself?

You can clear leaves, branches and snow from around the unit and from the outside of the grilles by hand. Vaillant’s aroTHERM plus instructions say to clean the casing with a damp cloth and a little solvent-free soap and not to use sprays, scouring agents, detergents, solvents or cleaners that contain chlorine. Daikin warns owners not to rinse the unit. Do not open the casing, hose the coil or touch the fan.

How often should I check the water pressure?

Daikin’s Altherma 3 user guide says to check regularly that it is above 1 bar. Vaillant’s fault-code guidance uses a normal range of 1 to 1.5 bar. Other brands set their own figures in the user manual. Write the reading down each time so you can spot a slow fall. See heat pump water pressure.

Is a maintenance contract worth having?

That is your choice. Vaillant’s aroTHERM plus instructions recommend making a maintenance contract and Daikin UK and Grant UK both describe their own service plans. Whatever you choose, the visit should follow the manufacturer’s instructions and leave you a dated record. Ask My Heatpump does not sell or recommend a particular plan.

Sources we checked

This is general guidance only. For faults or anything electrical, please contact a qualified heat pump engineer or the manufacturer of your system.