Heat Pump Water Pressure Too Low

Last reviewed: November 2026. Help for heat pump owners in the UK.

Short answer

Water pressure ranges are brand-specific, so start with your own user manual rather than a single figure for every heat pump. Daikin Altherma 3 M user guides ask owners to check regularly that pressure stays above 1 bar. Vaillant’s official F.22 guidance uses a cold filling range of 1.0 to 1.5 bar on many of its heat pumps and describes F.22 if the pressure falls too far. If pressure keeps dropping, stop topping up and call an engineer. Write the reading down with any error code.

Five points on Daikin and Vaillant official pressure figures and checking other brands in the user manual
Use the range in your own manual. This page only quotes official figures we have checked.

Use the range in your own manual

There is no single correct pressure for every UK heat pump. The owner figure belongs in the user manual for your model, and it may be given as a range, a minimum, or a cold filling pressure. Read the gauge when the system is in the state the manual describes, usually when it is cold. Write the number down.

Official figures we have checked and can quote are:

  • Daikin Altherma 3 M. The user reference guide asks you to check regularly that the water pressure is above 1 bar. The more detailed page is Daikin Altherma water pressure.
  • Vaillant. Official F.22 guidance says that if the water pressure is below the normal range of 1 to 1.5 bar, a competent owner can raise it slowly into that range, and that F.22 is the low-pressure fault. See Vaillant F.022 and M.32.

For Grant, Ideal, Samsung, Ecodan and MHI, this page does not invent a number. Use the range in your user manual and the brand error-code pillar if a low-pressure or low-flow code is showing.

If the pressure keeps falling

A single small top-up after a service or after bleeding radiators can be normal. Repeated topping-up is not. It can point to a leak, a failing expansion vessel or another fault that needs an engineer. Also see heat pump leaking water if you can see water.

Do not keep filling the system as a way to clear an error code. If the code returns, stop and use heat pump not working or heat pump help.

Use the chat above to ask a question about your heat pump. We do not pass your details on to installers.

FAQs

What pressure should my heat pump be at?

Use the figure in your own user manual. This page only quotes official ranges we have checked: Daikin Altherma 3 M user guides say to keep pressure above 1 bar, and Vaillant’s official F.22 page uses 1.0 to 1.5 bar when the system is cold on many of its heat pumps. A taller building can need a higher filling pressure: Vaillant says to ask a competent person in that case.

What is Vaillant F.22?

It is Vaillant’s low water pressure fault. The official fault-code page explains the range and the owner checks. Our detailed guide is Vaillant F.022 and M.32.

Can I top the pressure up myself?

Only if your user manual describes an owner filling loop and you are competent to use it. Vaillant’s official F.22 guidance allows a competent owner to raise a low reading into the published range, at their own risk. If you are not sure, or the pressure falls again, stop and call an engineer. Never keep adding water without finding out why it is dropping.

Why does low pressure matter?

Many heat pumps will reduce output or lock out if the water pressure or flow is too low, to protect the system. The exact lock-out point is brand-specific. If an error code is showing, write it down and use the brand error-code guide.

Sources we checked

This is general guidance only. For faults or anything electrical, please contact a qualified heat pump engineer or the manufacturer of your system.