The Altherma 3 family is the most common Daikin heat pump in UK homes. All the models share the same colour controller, which makes settings and error codes broadly consistent across the range.
The Altherma 3 family
- Altherma 3 R (ERGA outdoor): split system using R32. D series 2018–21, E series 2021 on. Also available as the 3 R ECH2O thermal store.
- Altherma 3 H HT (EPRA14–18): hydro-split, up to 70°C flow. Popular for radiator homes.
- Altherma 3 H MT (EPRA08–12E): hydro-split, radiator maximum 65°C.
- Altherma 3 H (EPGA11–16D): 11–16 kW, 2019–23, radiator maximum 60°C.
- Altherma 3 M (EBLA/EDLA): monobloc, all refrigerant outdoors.
Not sure which you have? See our model numbers guide.
The colour controller (MMI)
The same menu tree runs on all Altherma 3 models, with items hidden when not applicable:
- [0] Malfunctioning: help text for the active error.
- [1] Room and [2] Main zone: setpoint mode, weather curve, emitter type, control.
- [3] Additional zone.
- [4] Space heating/cooling: operation range, increase around 0°C, overshoot.
- [5] Tank: Powerful, setpoints, heat-up mode, disinfection.
- [7] User settings: time/date, holiday, quiet, electricity price.
- [8] Information: energy data, malfunction history, sensors.
- [9] Installer settings.
- [B] User profile, [C] Operation, [D] Wireless gateway (when WLAN fitted).
Turn on breadcrumbs to see screen numbers. Permission levels (User, Advanced user, Installer) are changed at [B]. We never share access codes; many items are installer-only.
Key settings to know
- Weather-dependent curve at [2.5]; shift the flow temperature by up to ±10°C from the home screen.
- Control mode at [2.9]: LWT, external thermostat or room thermostat.
- Hot water setpoints at [5.2]–[5.4], heat-up mode at [5.6].
- Water pipe freeze prevention at [9.7], which should stay on.
Common codes
Owner-checkable codes include 7H-01 (flow), AH-00 (disinfection), AJ-03 (slow heat-up), U8-01/U8-11 (app connection) and 89-02/03 (freeze-up warnings). See our error codes hub.
App control
E-series units come with a WLAN cartridge for Onecta; D-series units use a LAN adapter. See our Onecta guide.
Software updates
Owners report over-the-air updates via Onecta (for example 7.10.0 in June 2026, with settings kept). Daikin publishes few release notes.
FAQ
Are menus the same on every Altherma 3?
The tree is the same, but some items are hidden, and defaults differ by model.
Why can’t I find a setting?
Check your permission level at [B]; many items are installer-only.
Which Altherma 3 is best for radiators?
The 3 H HT reaches 70°C, but the best choice depends on your home’s design. Ask an installer.
Related guides
- Altherma 3 R guide
- Altherma 3 H HT guide
- Altherma 3 H MT guide
- Altherma 3 M monobloc guide
- Model numbers explained
- Altherma 3 vs 4