Daikin Altherma Model Numbers Explained

Before you change a setting or look up an error code, you need to know exactly which Altherma you have. Menus, defaults and code meanings differ between families, and even between series letters. The rating label holds the answer.

Where to find the rating label

Look for the rating plate on both the outdoor unit and the indoor unit (hydrobox, floor-standing unit or thermal store). Note both model codes, plus which screen you use: the unit’s own controller, a Madoka, or the Onecta app. It also helps to know whether you have radiators, underfloor heating or both, how many zones, whether it’s a hybrid, and the install year.

Decoding the letters

From Daikin’s model lists:

  • ER = split outdoor unit. EP = hydro-split outdoor unit. EB/ED = monobloc (EB reversible heat and cool, ED heating only).
  • H = heating only, X = heating and cooling (indoor units).
  • B = wall-mounted hydrobox, V = floor-standing with tank, Z = bi-zone, S = ECH2O thermal store.
  • Suffix 3V / 6V / 9W = backup heater 3 kW / 6 kW single-phase / 9 kW three-phase.
  • The series letter (CA, CB, D, E…) matters, because menus and codes differ.

Common UK models

Altherma 3 family (colour screen)

  • ERGA04–08D with EHBH/X or EHVH/X D: Altherma 3 R, D series (2018–21).
  • ERGA04–08E with EHBH/X, EHVH/X or EHVZ E: Altherma 3 R, E series (2021 on), WLAN cartridge supplied.
  • ERGA with EHSH/X(B) P30/P50E: Altherma 3 R ECH2O thermal store.
  • EPRA14–18 D/E with ETBH/X, ETVH/X, ETVZ or ETSH/X: Altherma 3 H HT, up to 70°C.
  • EPRA08–12E with ETBH/X12E: Altherma 3 H MT.
  • EPGA11–16D with EABH/X, EAVH/X or EAVZ: Altherma 3 H (2019–23).
  • EBLA/EDLA04–08E or 09–16D: Altherma 3 M monobloc.

Altherma 4

  • EPSK06–14A (2025) or compact EPSKS04/06/07A (2026) with EPSX(B), EPVX or EPBX: Altherma 4 H using R290 (propane), with a 5-inch touchscreen.

Hybrid

  • EVLQ05/08CA with EHYHBH/X or CHYHBH05/08AF, and EJHA04AAV3 with EHY2KOMB28/32AA: Altherma Hybrid with a Daikin gas boiler.

Older systems

  • ERLQ/ERHQ with EHBH/X CB, or EBLQ/EDLQ C: LT second generation (2014–19), EKRUCBL text controller.
  • ERHQ/ERLQ with EHBH/X16CA: LT split 2012 update, EKRUCAL controller.
  • ERYQ/ERHQ/ERLQ with EKHBH/X A/B: LT first generation (2006–13), push-button LCD.
  • ERRQ/ERSQ with EKHBRD: HT first generation, up to 80°C.
  • EHSH/X(B) A/B with RoCon HP: early ECH2O units.

Why it matters

  • Menus differ. Altherma 3 uses menus [0]–[D]; Altherma 4 uses [1]–[13]; text controllers use a different tree again.
  • Defaults differ. For example, maximum flow defaults to 55°C on 3 R but 70°C on 3 H HT.
  • Error meanings differ. Some codes exist only on certain families.
  • App support differs. Some models use a WLAN cartridge, others a LAN adapter, and older units aren’t supported.
  • Frost protection differs. Monobloc systems need glycol or anti-freeze valves on outdoor pipes.

FAQ

What does ERLQ versus ERHQ mean?

On LT second generation, ERLQ is the cold-climate outdoor unit with a factory bottom plate heater; ERHQ doesn’t have one (it’s an option).

I can’t read the label. What now?

Check your MCS paperwork or handover pack, or the dealer information at [8.3] on Altherma 3.

Does the series letter really matter?

Yes. D and E series Altherma 3 R units differ in app connection and curve types, for example.