The 8H codes relate to water getting hotter than the unit expects. They’re engineer codes on most models, but one Altherma 4 variant is completely normal.
What 8H means
- Altherma 3, 8H-00 (and 8F-00): abnormal rise in outlet water temperature.
- 8H-01: over- or undercooling of the mixed circuit.
- 8H-02: mixed circuit thermostat.
- 8H-03: water circuit thermostat.
- First-generation LT, “8H”: outlet water above 65°C.
- Altherma 3 R ECH2O: also lists 8H-08.
- Altherma 4: 8H-00 to 8H-03 and 8H-10/11 are overheating codes, but 8H-09 is a normal backup heater relay check at start-up, not a fault.
What owners can do
Daikin doesn’t give an owner fix for 8H, so don’t change settings to try to clear it. Sensibly:
- Note the exact code, time and what the system was doing (heating, hot water, after a disinfection cycle).
- Check pressure is above 1 bar and valves are open.
- Mention any other heat source connected to the system, such as a boiler or stove; Daikin’s service manual lists an external heat source raising water temperature as a cause for the related AA-01 code.
- Photograph the help text and [8.2] history, then call your installer.
FAQ
Is 8H dangerous?
It’s a protection. The unit is reacting to high water temperature. Leave diagnosis to an engineer, as it can involve thermostats, sensors and the backup heater.
My Altherma 4 shows 8H-09 at start-up. Is something wrong?
No. Daikin lists 8H-09 as a normal relay check of the multistep backup heater.
Can I keep resetting it?
No. If 8H returns after one reset, stop and get it checked.
What to tell your engineer
A few details make diagnosis faster and can save a second visit:
- Your outdoor and indoor model codes from the rating labels.
- The full code (for example XX-YY), with a photo of the help text and the malfunction history.
- When it happened and what the system was doing: heating, hot water, defrost or starting up.
- The pressure gauge reading, and whether any valves or radiators were recently touched.
- Whether the code cleared on its own, came back after a reset, or appeared alongside other codes.
- Any recent power cuts, storms or very cold, damp weather.
Related guides
- Daikin Altherma error codes hub
- Backup heater explained
- How to reset an error code
- Troubleshooting guide
Safety first
Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer (F-gas certified for refrigerant work, and R290-competent for Altherma 4).
Still stuck?
Ask the Heat Pump Assistant with your model code and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.