This page brings together the most common Altherma problems owners ask about, with the quick checks for each and where to read more.
Start here: identify your model
Menus and codes differ by family. See our model numbers guide.
House cold
Errors, pressure above 1 bar, TRVs open, heating on and below [4-02], try a +1/+2 shift, then raise the cold end ([1-02]) if cold only in cold weather. See house still cold.
No hot water
Errors (7H-04, AJ-03, AH-00, AA), tank switched on, heat-up mode and schedule, setpoints. See not heating water.
High bills
Curve too high, backup heater use, hot water temperature and frequency, quiet mode, cycling, closed zones. See backup heater and high bills.
Short cycling
Lower the mild end, open TRVs, reduce zoning, review control mode. See short cycling.
Steam and whooshing
Normal defrost. Report defrosts every few minutes, over 20 minutes or leaving ice. See defrost cycle.
Noises
Hum, defrost hiss, valve clicks are normal. Grinding, banging, knocking or persistent gurgling: report. See quiet mode and noise.
Pressure dropping
Above 1 bar, below 3 bar. Repeated loss, a dripping relief valve or HJ-10: installer. See water pressure.
App offline
Heating carries on. Router first; 2.4 GHz only; U8-01/U8-11. See Onecta setup.
Can’t find a menu item
Check permission level ([B] on Altherma 3; [5.13] Advanced settings on Altherma 4). Many items are installer-only.
Error codes
Explain only what your model’s documentation says; if a code isn’t listed, don’t guess. See the error codes hub and how to reset.
Should I switch off when I’m out?
Usually not. A 2–3°C setback at most.
Should I turn off the legionella cycle?
No; talk to your installer.
FAQ
What info should I gather before calling?
Model codes, error photos with times, pressure reading and what the system was doing.
Is it safe to bleed radiators?
Yes if you’re confident; recheck pressure afterwards.
When is it definitely an engineer job?
Refrigerant, electrics, opening the unit or internal resets.
Related guides
Safety first
Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer (F-gas certified for refrigerant work, and R290-competent for Altherma 4).
Still stuck?
Ask the Heat Pump Assistant with your model code and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.