Daikin Altherma Troubleshooting Guide for Owners

This page brings together the most common Altherma problems owners ask about, with the quick checks for each and where to read more.

Start here: identify your model

Menus and codes differ by family. See our model numbers guide.

House cold

Errors, pressure above 1 bar, TRVs open, heating on and below [4-02], try a +1/+2 shift, then raise the cold end ([1-02]) if cold only in cold weather. See house still cold.

No hot water

Errors (7H-04, AJ-03, AH-00, AA), tank switched on, heat-up mode and schedule, setpoints. See not heating water.

High bills

Curve too high, backup heater use, hot water temperature and frequency, quiet mode, cycling, closed zones. See backup heater and high bills.

Short cycling

Lower the mild end, open TRVs, reduce zoning, review control mode. See short cycling.

Steam and whooshing

Normal defrost. Report defrosts every few minutes, over 20 minutes or leaving ice. See defrost cycle.

Noises

Hum, defrost hiss, valve clicks are normal. Grinding, banging, knocking or persistent gurgling: report. See quiet mode and noise.

Pressure dropping

Above 1 bar, below 3 bar. Repeated loss, a dripping relief valve or HJ-10: installer. See water pressure.

App offline

Heating carries on. Router first; 2.4 GHz only; U8-01/U8-11. See Onecta setup.

Can’t find a menu item

Check permission level ([B] on Altherma 3; [5.13] Advanced settings on Altherma 4). Many items are installer-only.

Error codes

Explain only what your model’s documentation says; if a code isn’t listed, don’t guess. See the error codes hub and how to reset.

Should I switch off when I’m out?

Usually not. A 2–3°C setback at most.

Should I turn off the legionella cycle?

No; talk to your installer.

FAQ

What info should I gather before calling?

Model codes, error photos with times, pressure reading and what the system was doing.

Is it safe to bleed radiators?

Yes if you’re confident; recheck pressure afterwards.

When is it definitely an engineer job?

Refrigerant, electrics, opening the unit or internal resets.

Related guides

Safety first

Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer (F-gas certified for refrigerant work, and R290-competent for Altherma 4).

Still stuck?

Ask the Heat Pump Assistant with your model code and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.