Last reviewed: November 2026. Help for Daikin Altherma owners.
Short answer
A6 is a code from the older, first-generation Daikin Altherma HT (high temperature) system: the EKHBRD indoor unit paired with an ERRQ or ERSQ outdoor unit. Daikin’s manuals call it a “malfunction of pump in water circuit (M1P)”. It usually means the water pump cannot turn or water is not moving properly. You can check the water pressure and make sure valves and radiators are open. Anything inside the unit is a job for an engineer. On Altherma 3 and Altherma 4 models, A6 is not in the error lists we checked. Water flow problems on those models show as a 7H code instead.
First, check which Altherma you have
The same code can mean different things on different Daikin products, so start with the model number. It is on the rating label on the indoor unit and the outdoor unit. Our guide to reading your Daikin Altherma model number explains how.
| Your system | What A6 means |
|---|---|
| First-generation Altherma HT: EKHBRD011, 014 or 016 (AB, AC or AD versions) indoor unit with an ERRQ or ERSQ outdoor unit | Pump error in the water circuit (pump M1P), or another water system error |
| Altherma 3 (R, M, H HT, H MT), Altherma 4, Altherma LT second generation, first-generation Altherma LT (EKHBH/EKHBX), EBLQ/EDLQ monobloc, Hybrid and Altherma 3 Geo | We found no A6 in the error lists of the Daikin manuals we hold for these models. A water flow problem on these shows as 7H. If your screen shows A6, check the full code and your model again, and ask your installer. |
| A Daikin air conditioner or fan coil unit (not an Altherma heat pump) | Indoor fan motor problem. This is a different product with a different code list. |
This page does not cover every Daikin manual. Always check the error list in the manual for the exact model on your rating label. Our guide to finding the right Daikin Altherma manual can help.
What A6 means on the Altherma HT
The first-generation Altherma HT has a water pump inside the indoor unit. Daikin’s service manual says the unit shows A6 when:
- it cannot detect the pump turning, even when it sends the pump full power, or
- the water temperatures it measures are outside the range it expects. For example, the leaving and return water are less than 1°C apart, which suggests water is not moving properly.
Causes Daikin lists
Daikin’s service manual gives three likely causes:
- The pump is stuck (the rotor is locked).
- The wiring between the pump and the indoor unit’s circuit board is loose, disconnected or faulty.
- Water flow is blocked, or the water side of the heat exchanger is blocked.
The service manual’s checks also include closed valves, a clogged filter, water pressure outside its stated range (0.3 to 3 bar) and air in the system. If none of those is the problem, it tells the engineer to check the pump wiring, then the circuit board or the pump itself.
What you can safely check
1. Read the water pressure
Read the pressure gauge while the system is cold. In the owner maintenance section of the EKHBRD-AD operation manual, Daikin says to check that the gauge reads above 1 bar. If it is low, see our guide to Daikin Altherma water pressure. Only top up if your installer has shown you how.
2. Check valves and radiators are open
Daikin’s first step for A6 is to make sure water can flow, with all valves in the circuit open. Check that radiator valves and any zone valves have not all been turned off.
3. Think about recent work
If A6 appeared soon after the system was drained, refilled or serviced, a valve may have been left closed or air may be trapped. Tell whoever did the work.
4. Reset once
Daikin’s installation manual says to reset the safety with the button shown in its error code section. If that does not clear it, contact your installer. Reset once only. If A6 comes back, stop and call an engineer.
Leave these to an engineer: Daikin’s installation manual also says to force clean water through the unit (flushing it). That means opening the water circuit, so it is not an owner job. The same goes for bleeding air from inside the unit, cleaning filters and any work on the pump, its wiring or the circuit board. These involve live parts and draining water.
A related code on the same models: AE
On the first-generation Altherma HT, Daikin’s service manual lists AE as a water circuit error. The causes are a blocked water flow or heat exchanger, a 3-way valve in the wrong position, or a water circuit that is too hard for the built-in pump to push water around. The owner checks are the same as for A6. If AE keeps coming back, an engineer needs to look at the pipework design.
When to call an engineer
Call a qualified heat pump engineer if:
- A6 comes back after one reset
- the pressure is fine and all valves are open, but the code stays
- the pressure keeps dropping or you see water leaking
- you hear grinding or humming from the indoor unit, or smell burning
FAQs
What does A6 mean on a Daikin Altherma?
On the first-generation Altherma HT (EKHBRD indoor unit with ERRQ or ERSQ outdoor unit), Daikin describes A6 as a malfunction of the pump in the water circuit, or another water system error. It is not in the error lists we checked for Altherma 3 or Altherma 4.
Is A6 the same as 7H?
They are not the same code, but both are about water moving through the system. A6 belongs to the older Altherma HT. On Altherma 3 and other current models, low water flow shows as 7H.
My Altherma 3 shows A6. What does that mean?
A6 is not in the Altherma 3 error lists we checked. Write down the full code exactly as shown, including any sub-code, and check the model on the rating label. Make sure the code is on the heat pump’s controller and not on another Daikin unit, such as an air conditioner. Then ask your installer.
Can I fix an A6 pump fault myself?
You can check the pressure and make sure valves are open, then reset once. Freeing a stuck pump, checking wiring and flushing the system are engineer jobs.
Should I keep resetting A6?
No. Reset once. If it comes back, the cause needs finding.
What to tell your engineer
- Your indoor and outdoor model codes from the rating labels (for example EKHBRD and ERRQ or ERSQ).
- The exact code shown, with a photo of the controller.
- The pressure gauge reading, and whether any valves or radiators were recently touched.
- Whether the code cleared after a reset, came back, or appeared alongside other codes such as AE.
- Any recent draining, refilling or service work.
Related guides
Sources we checked
These manuals back up the A6 and AE details on this page. They do not replace the book for the model on your rating label, and they do not cover every sentence on this page.
- Daikin installation manual, EKHBRD011–016ADV17/Y17, 4P402191-1B (2017.09), printed page 37: A6 “Malfunction of pump in water circuit (M1P)”, corrective action and reset instruction.
- Daikin installation manual, EKHBRD011–016 ABV1/Y1 and ACV1/Y1, 4PW60970-1D (05.2011), printed page 37: same A6 entry.
- Daikin operation manual, EKHBRD011–016ADV17/Y17, 4P402192-1B (2017.09): owner maintenance, check the gauge reads above 1 bar.
- Daikin service manual ESIE09-08C, Altherma HT (ERSQ/ERRQ + EKHBRD), printed pages 133–135: A6 detection, causes and troubleshooting; AE water circuit error. This copy is hosted by a third party, not Daikin.
- Daikin ARC485B2 remote controller operation manual, 3P748484-4B (fan coil units): A6 “Indoor fan motor abnormal”. This applies to air conditioning and fan coil products, not Altherma.