Ideal Logic Air Fault Codes: What Owners Can Check

Ideal’s Logic Air heat pump flags problems with an alarm on its control box display. This guide covers the Logic Air 4, 5, 8 and 10 kW models, using Ideal’s user guide UIN 235468 A07 and the Installation and Maintenance manual UIN 241428. It explains how to read the alarm, what the common codes mean and who to contact.

How to see the alarm

  • An alarm bell icon appears on the control box home screen.
  • Open System Information to see the active alarm.
  • Ideal’s user guide lists the controller fault numbers and the heat pump faults F0 to F27. Heat pump faults show under controller code 370.

Common heat pump faults

  • F27 – No water flow fault: the heat pump cannot see water moving. Check that the system pressure is normal and no valves have been closed.
  • F26 – Flow sensor error: the flow-measuring sensor has a problem. This needs an engineer.
  • F24 – Circulation pump error: a fault with the pump. This needs an engineer.
  • F15 – Air flow fault: air through the outdoor unit is restricted. Check the grilles are clear of leaves, snow or anything stored against them.

Controller fault numbers worth knowing

  • 10: outside sensor fault. Weather compensation relies on this sensor.
  • 127: anti-legionella temperature fault. The weekly cycle did not reach temperature.
  • 490, 499, 516: no outdoor connection.

Other codes are in the user guide’s fault table. Check the exact code against that table rather than guessing.

Owner checks before you call

  • Pressure: Ideal’s commissioning fill is 1–1.5 bar, and the minimum system pressure printed is 0.5 bar.
  • The outdoor unit is clear, with no ice blocking it.
  • The heating curve and setpoints have not been changed. Ideal’s troubleshooting chart suggests checking this.
  • Steam from the outdoor unit during defrost is normal, not a fault.

Who to contact

Ideal’s user guide says to contact Ideal if the heat pump is under warranty, and otherwise your installer. The fault history (the last ten faults) is kept at installer level, so the engineer can read past events.

FAQ

Can I reset a Logic Air fault myself?

Ideal routes repeat faults to Ideal or your installer. Don’t keep cycling the power to clear one.

Is steam from the fan a fault?

No. Ideal states a plume of steam during defrost is normal. Keep clear of the unit while it happens.

What to tell your engineer

  • Your model size (4, 5, 8 or 10 kW) and serial number.
  • The exact code, with a photo of the System Information screen.
  • The pressure reading and whether any valves were touched.
  • Whether it happened in heating, hot water or defrost.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Ideal Logic Air Heat Pump User Guide UIN 235468 A07 (06/2024): p3–4, p9–11 (printed = PDF). Official PDF
  • Ideal Logic Air Installation and Maintenance manual UIN 241428: p25 and p50 (printed = PDF); p72 (printed = PDF). Official PDF

Related guides

Safety first

Owners can use the controls, read alarms, check pressure and keep the outdoor unit clear. Refrigerant work needs a Category I or II F-gas engineer, and electrical, internal and installer-level settings are for a qualified engineer.

Still stuck?

Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.

Independent guide, not affiliated with or endorsed by Ideal.