The Halo Air is Ideal’s programmable room thermostat for the Logic Air heat pump. Ideal’s user guide says the heat pump’s control box gives only a limited interface, and the room thermostat handles day-to-day control. This guide covers the single-zone Halo Air (RF UIN 234819 and Wi-Fi UIN 234790) using Ideal’s installation manual 234829 A06 and quick user guide 260218.
How it connects
- The Halo Air talks wirelessly (Zigbee) to a Smart Interface, which connects to the heat pump over a BSB link.
- The thermostat runs on 4 AA batteries.
- Ideal recommends mounting it 1.2–1.5 m high, within about 30 m of the interface. A Zigbee booster (221132) is available for difficult layouts.
- The Wi-Fi version works with Ideal’s app over 2.4 GHz Wi-Fi.
Modes and default temperatures
- Auto follows the schedule. Manual holds one temperature. Off still protects against frost at 8°C.
- Defaults are comfort 21°C, setback 18°C and frost 8°C.
- The default schedule is comfort 06:00–08:00 and 16:00–22:00, with setback at other times.
- You can override the current period without changing the schedule.
Useful menu features
- Holiday mode, timed schedules (up to six periods a day) and a plus-hours boost.
- Hot water and energy data views. Timed hot water is disabled by default.
- Optimised start can begin heating up to 3 hours early to reach comfort on time.
- A temperature offset of ±2.5°C corrects a reading that is slightly off.
Status lights and resets
If the LED key shows heat pump communication off, Ideal points to the BSB wiring, which is an installer check. The manual also describes a paperclip reset and Zigbee re-pairing. Ask your installer before re-pairing, because it disconnects the thermostat.
Weather compensation note
We do not publish Halo Air weather compensation menu steps, because the Halo manuals we hold do not print them. Combined weather and room compensation is set up on the Logic Air itself. See our Logic Air weather compensation guide.
FAQ
Does Off mean the heat pump is fully off?
No. In Off, the Halo Air still keeps 8°C frost protection.
Why does heating come on before my schedule?
Optimised start can start up to 3 hours early so the room reaches comfort temperature on time.
Manual references
Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.
- Ideal Halo Air Single Zone Installation and Servicing manual UIN 234829 A06: PDF p3, p5, p12, p14–17, p19 (no printed page numbers seen). Official PDF
- Ideal Halo Air Quick User Guide 260218: PDF p1–2. Official PDF
- Ideal Logic Air Heat Pump User Guide UIN 235468 A07 (06/2024): p3 (printed = PDF). Official PDF
Related guides
- Ideal Logic Air Weather Compensation Explained
- Ideal Logic Air Hot Water and Legionella Settings
- Ideal Logic Air Running Costs: Efficiency Checks
Safety first
Owners can use the controls, read alarms, check pressure and keep the outdoor unit clear. Refrigerant work needs a Category I or II F-gas engineer, and electrical, internal and installer-level settings are for a qualified engineer.
Still stuck?
Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.
Independent guide, not affiliated with or endorsed by Ideal.