Ideal Logic Air Running Costs: Efficiency Checks

We do not quote prices, because tariffs change. Ideal’s own performance data does show what drives Logic Air running costs: the lower the flow temperature, the more heat you get per unit of electricity. This guide uses Ideal’s Logic Air power charts and Installation and Maintenance manual UIN 241428.

What Ideal’s COP charts show

For the 8 kW Logic Air at 0°C outside, Ideal’s chart gives these coefficients of performance (COP):

  • 30°C flow: 3.98
  • 35°C flow: 3.39
  • 40°C flow: 2.94
  • 45°C flow: 2.59
  • 50°C flow: 2.32
  • 55°C flow: 2.08

Going from 55°C to 40°C flow improves the COP by around 40% at that condition. Other models and conditions differ, so treat these as an illustration, not a guarantee for your home.

Settings that keep flow temperature down

  • Weather compensation: always active on the Logic Air. A well-set curve avoids running hotter than needed. The default maximum flow is 55°C.
  • Room influence: with a Halo Air, room feedback can trim the flow (default 20%).
  • Setback: Halo Air defaults are 21°C comfort and 18°C setback. Small setbacks suit heat pumps better than switching off.

Hot water habits

  • The default hot water target is 50°C. Raising it lowers efficiency.
  • The legionella cycle and the immersion via Special operations use direct electric heat. Keep immersion boosts occasional.

Keep it working efficiently

  • A clear outdoor coil and a clean filter keep flow healthy.
  • Ideal recommends servicing at least annually.
  • A steam plume during defrost is normal and not wasted running.

FAQ

What COP will my Logic Air get?

It depends on model, weather and flow temperature. Ideal’s charts give figures for each condition, and the values above are one example.

Is it cheaper to turn the heating off when I’m out?

Usually a modest setback is better. Compare bills over a full year after any change.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Ideal Logic Air Power Charts (COP): PDF p2–5. Official PDF
  • Ideal Logic Air Installation and Maintenance manual UIN 241428: p52 (printed = PDF), Table 15; p67–68 (printed = PDF). Official PDF
  • Ideal Logic Air Heat Pump User Guide UIN 235468 A07 (06/2024): p4 and p7–8 (printed = PDF). Official PDF
  • Ideal Halo Air Quick User Guide 260218: PDF p1–2. Official PDF

Related guides

Safety first

Owners can use the controls, read alarms, check pressure and keep the outdoor unit clear. Refrigerant work needs a Category I or II F-gas engineer, and electrical, internal and installer-level settings are for a qualified engineer.

Still stuck?

Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.

Independent guide, not affiliated with or endorsed by Ideal.