MHI Hydrolution Alarms: RC-HY Status Lamp and Codes

Mitsubishi Heavy Industries (MHI) Hydrolution heat pumps report problems through the RC-HY20-W or RC-HY40-W control module. This guide covers Hydrolution (HM) systems using MHI’s user’s manual PSB012A016B. Numbered alarm meanings come from the January 2022 installation manual PSC012D169, which covers HSB60-W/HSB100-W with FDCW60/71VNX-W. Check your plate before relying on a number. MHI is a separate company from Mitsubishi Electric.

How an alarm shows

  • The status lamp changes from green to red, and an alarm bell appears in the information window.
  • Turn the control knob and press OK to see the alarm type and options.
  • A yellow lamp means emergency mode. A green lamp with a technician symbol is an information message that resets itself once the cause is fixed.

Your three options

  • info / action: explains the alarm and gives tips to correct it.
  • reset alarm: often enough. If the lamp turns green, the alarm is cleared. If the alarm disappears and returns, contact your installer.
  • aid mode: an emergency mode that keeps heat and hot water going, possibly with only the electric addition. It does not fix the fault, and the lamp stays red.

Numbered alarms (PSC012D169 systems)

  • 1: outdoor sensor (BT1) fault. Supply temperature drops to minimum.
  • 162 / 163 – high condenser out / in: causes include an incorrectly set heating curve, low heating medium flow or an undersized heating system.
  • 212: compressor hasn’t run for a week.
  • 220 – high pressure alarm: causes include insufficient air circulation or a blocked heat exchanger, and low or no flow during heating.
  • 221: low pressure alarm. 224: outdoor fan alarm. 225: flow and return sensors mixed up.

Owner basics before calling

MHI suggests checking the switch position, the house’s group and main fuses, the earth circuit breaker and any load monitor. If 162 or 163 is in the alarm log and rooms are cold, the flow across the heat pump may need adjusting by your installer.

FAQ

Is aid mode safe to leave on?

It’s meant as a stopgap while you wait for help. Running on electric addition costs more, so call your installer.

Do these numbers apply to my EZY, HMA, HMS or a later outdoor?

Not necessarily. The numbered list is only from PSC012D169 (January 2022) for HSB60-W with FDCW60VNX-W and HSB100-W with FDCW71VNX-W. The later installation manual PSC012D169A (December 2023) also lists HMA60/100-W, HMS60/100-W, FDCW60/71VNX-A and FDCW100VNX-A, and it does not print this numbered alarm table. Do not apply the D169 numbers to those D169A-only pairings, or to EZY or HSB140. Follow the on-screen info for other models.

What to tell your engineer

  • The product’s 14-digit serial number, which MHI says to always give.
  • The indoor and outdoor model and the controller (RC-HY20-W or RC-HY40-W).
  • The alarm text and number, with a photo.
  • Whether reset or aid mode was used.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Mitsubishi Heavy Industries Hydrolution (HM) user’s manual PSB012A016B (2024-08): EN-8 and EN-36–37 (PDF p10 and p38–39). Official PDF
  • Mitsubishi Heavy Industries Hydrolution (HM) R32 installation manual PSC012D169 (2022-01): printed p76, p78 and p84 (PDF p78, p80 and p86). Official PDF
  • Mitsubishi Heavy Industries Hydrolution (HM) installation manual PSC012D169A: cover (PDF p1); numbered alarm table searched (none found). Official PDF

Related guides

Safety first

Owners can use the RC-HY controller, read alarms and keep the units clear. Electrical, refrigerant (R32/R410A) and internal work is for a qualified engineer, so contact your dealer or installer.

Still stuck?

Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.

Independent guide, not affiliated with or endorsed by Mitsubishi Heavy Industries.