MHI Hydrolution RC-HY20-W and RC-HY40-W Controls Guide

The RC-HY20-W and RC-HY40-W are the control modules for Mitsubishi Heavy Industries Hydrolution (HM) systems. They run the heat pump, circulation pumps, reversing valves and any additional heater. MHI says RC-HY40-W functions are the same as on HMA and HMS units. This guide follows MHI’s user’s manual PSB012A016B.

The display unit

  • Status lamp: green in normal operation, yellow in emergency mode, red for an alarm.
  • Control knob: scroll menus and change values. OK confirms, and Back goes back or cancels an unconfirmed change.
  • Switch (SF1): On, Standby or Emergency mode. Use Emergency mode only for a fault on the control module. It turns the compressor off and uses the immersion heater.
  • USB port: behind the badge, for software updates.

Main menus

  • 1 Indoor climate: temperature, scheduling and advanced settings such as the heating curve.
  • 2 Hot water: temporary lux, comfort mode and scheduling. This only appears if a water heater is docked.
  • 3 Info: information about how the installation is running.
  • 4 My installation: includes operating mode (4.2), holiday (4.7) and operating prioritisation (4.9.1).

Advanced menus have orange text and are meant for experienced users. Service settings are for installers.

Setting the temperature (menu 1.1)

  • With a room sensor: set the desired room temperature from 5 to 30°C (default 20°C).
  • Without a room sensor: you set a heating curve offset from −10 to +10 (default 0). Usually one step changes room temperature by about a degree.
  • MHI warns that underfloor heating may not suit control by the room sensor.

Scheduling (menu 1.3)

You can schedule up to three periods per day for each weekday, with a separate schedule per climate system on RC-HY40-W, HMA and HMS. Holiday settings take priority over schedules.

Tips from MHI

  • Open radiator or underfloor thermostats fully, except where you want cooler rooms such as bedrooms.
  • Wait 24 hours between changes so the house can settle.

FAQ

The status lamp is yellow. What does that mean?

Emergency mode is on. Check the SF1 switch position, and call your installer if you didn’t select it.

Why can’t I see the hot water menu?

It only appears when a water heater is docked to the heat pump.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Mitsubishi Heavy Industries Hydrolution (HM) user’s manual PSB012A016B (2024-08): EN-8 (PDF p10); EN-9, EN-13–14 and EN-16 (PDF p11, p15–16 and p18); EN-21 and EN-36–37 (PDF p23 and p38–39). Official PDF

Related guides

Safety first

Owners can use the RC-HY controller, read alarms and keep the units clear. Electrical, refrigerant (R32/R410A) and internal work is for a qualified engineer, so contact your dealer or installer.

Still stuck?

Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.

Independent guide, not affiliated with or endorsed by Mitsubishi Heavy Industries.