Vaillant aroTHERM plus systems show three kinds of code on the indoor unit: S. codes are status messages, M. codes are maintenance messages and F. codes are faults. Most S. codes are perfectly normal. This guide covers the aroTHERM plus /6 and aroTHERM Split generation.
First, where is the code showing?
- On the indoor unit (VWZ AI wall box, uniTOWER plus or hydraulic station): these are the heat pump’s own codes, covered below.
- On the sensoCOMFORT controller: F.5034 to F.5049 mean the ventilation unit is reporting a fault (only if you have mechanical ventilation). See that unit’s own instructions. Other controller codes refer to communication with modules or the internet gateway (for example F.900, internet module communication interrupted).
Codes you can safely check yourself
- F.022 Water pressure too low: below about 0.5 bar, and the heat pump stops. Check the gauge or Live Monitor. Top up only if your installer has shown you how.
- M.32 Water pressure low: below about 0.7 bar. A warning before F.022.
- F.723 Building circuit: Pressure too low: printed in the same indoor-unit operating instructions. If filling pressure falls below the minimum pressure, the heat pump switches off. It is not described as an older rename of F.022.
- F.718 / F.785 Fan blocked: the fan hasn’t started after several tries. Look for snow, ice or debris at the grilles without opening anything.
- F.741 Return temperature too low: during de-icing the return fell below 13 °C (the message stays until the return is above 20 °C). Make sure radiator and zone valves are open.
- F.9998 Connection fault: heat pump: the indoor and outdoor units aren’t talking, or the outdoor unit has no power. Check the outdoor isolator and fuse board for a tripped breaker.
Codes for your installer
Explain the code to your installer and let them take it from there:
- Flow and hydraulics: F.788 pump locked out, F.820 no signal from the pump, F.731 high-pressure switch tripped (often too little water flow).
- Refrigerant circuit: F.729, F.732, F.733, F.734, F.735, F.737 and F.823 all relate to the refrigerant running outside its normal range. The unit restarts itself; repeats need an engineer.
- Inverter and power: F.817 compressor or inverter defect, F.818 mains voltage out of range, F.819 inverter overheated, F.752 and F.753 inverter faults, F.1117 compressor phase failure.
- Valves: F.755 4-port valve not in position, F.582 expansion valve fault.
- Sensors: F.514, F.517, F.519, F.520, F.526, F.546, F.585, F.703, F.774, F.821, F.825, F.073 and F.094.
- Back-up heater: F.1100 safety cut-out open. Never try to reset it inside the unit. F.1120 back-up heater phase failure.
Lhm. 37 and the spanner symbol
Lhm. 37 means comfort protection: a permanent fault was found and the unit is running in a restricted mode, often on the back-up heater. It keeps the house warm, but running costs rise. Call your installer with the code.
The only owner reset
There’s no on/off switch on the indoor unit. A full power-off at the isolator or fuse board, waiting at least 30 seconds, then switching back on, is the only reset an owner should do. If the code returns, call your installer.
FAQ
Is an S. code a fault?
No. S. codes are status messages. S.516, for example, just means defrost is running.
My code isn’t listed here. What does it mean?
We’d rather not guess. Note the exact code and where it shows, then check your manual or ask your installer.
What to tell your engineer
A few details make diagnosis faster and can save a second visit:
- Your outdoor model from the data plate (for example VWL 75/6 A) and your indoor unit and controller.
- The full code and where it shows (indoor unit or sensoCOMFORT), with a photo of the screen and the Live Monitor.
- When it happened and what the system was doing: heating, hot water, defrost or starting up.
- The water pressure reading, and whether any valves or radiators were recently touched.
- Whether the code cleared on its own, came back after a power-off, or appeared alongside other codes.
Related guides
- aroTHERM plus status (S.) codes
- F.022 low water pressure
- F.718 fan blocked
- F.741 return temp too low
- aroTHERM not heating: checks to try first
- aroTHERM with radiators: what to expect
Safety first
Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer. aroTHERM plus and aroTHERM pro units use R290, so refrigerant work needs an engineer competent with flammable refrigerants.
Still stuck?
Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.
Independent guide, not affiliated with or endorsed by Vaillant.