Vaillant aroTHERM With Radiators: What to Expect

Last reviewed: November 2026. Help for Vaillant aroTHERM plus owners in the UK.

Short answer

Radiators on a Vaillant aroTHERM plus usually feel cooler than they did on a boiler and that is expected. Vaillant’s aroTHERM plus handover guide says the water in the heating system will be between 35 and 55°C rather than the 60 to 70°C of a traditional boiler and that radiators are sized to keep each room warm. Weather compensation is standard, so radiators get warmer as it gets colder outside. Vaillant asks owners not to change the installer’s detailed settings. If one room stays cold, check the valves and the schedule, then talk to your installer about radiator size and the heat curve.

Bar chart comparing a traditional boiler at 60 to 70°C with an aroTHERM plus at 35 to 55°C heating water
Ranges from Vaillant’s aroTHERM plus handover guide.

Why aroTHERM radiators feel cooler

A heat pump runs the heating water cooler than a boiler, which is why the radiators feel milder to the touch. Vaillant publishes a few slightly different figures for this in different documents, so here they are as written:

  • The aroTHERM plus handover guide says the water in your heating system will be between 35 and 55°C, rather than the 60 to 70°C of a traditional fossil-fuelled boiler and that radiators will feel cooler but are sized to keep each room warm and comfortable, even on the coldest days.
  • Vaillant’s homeowner FAQs say heat pumps run between 45 and 55°C in the radiators, where a boiler would normally run at 60 to 70°C.
  • Vaillant’s modernise your home page says radiators work with an average flow temperature of 50°C, underfloor heating needs 35°C and a flow temperature of 45°C or below gives a very efficient system.

Vaillant also says the R290 aroTHERM plus can reach flow temperatures of up to 75°C, which it presents as useful for existing homes with older radiators. That is what the unit can do, not the temperature your system was designed to run at. Vaillant’s own advice is that the lower the flow temperature, the more efficient the system.

Weather compensation and your radiators

Vaillant’s handover guide says your heat pump system will have weather compensation as standard. When it is warmer outside the flow temperature is lower and the radiators feel cooler. When it is colder outside the flow temperature rises and the radiators get hotter. That is the system doing its job, not a fault.

Illustrative line showing flow temperature falling as the outdoor temperature gets milder
Colder outside means warmer radiators. Your installer sets the curve.

The curve that controls this is set by your installer. Our Vaillant heat curve guide explains how it works and Room temp. mod. covers the room-sensor option.

Radiator size and flow

Vaillant’s homeowner FAQs say the installer should do a room-by-room heat loss calculation using the MCS MIS 3005 method, then recommend any changes, which may include replacing radiators. They also say the radiators need pipework that allows good flow, because heat pumps need the water to move more quickly and that the installer will check the radiators are the correct size for the lower flow temperatures.

Energy Saving Trust makes the same point in general terms: radiators that were fine on a boiler may not be big enough at heat pump temperatures and larger or double and triple panel radiators give more surface area without taking up more wall.

If a room stays cold

Checklist of five checks when one room stays cold with a Vaillant aroTHERM and radiators
Start with the schedule and valves before you think about new radiators.

Check the schedule and set-back

Vaillant’s handover guide uses a comfort temperature with a set-back 3 or 4°C lower, for example 21°C and then 18 or 17°C. A room that feels cold only at certain times may simply be in a set-back period.

Check the valves

Make sure the radiator valve in that room is open and that zone valves are as your installer set them. Closing radiators in other rooms can restrict flow. If a return-temperature code shows during de-icing, see F.741 return temperature too low.

Check for codes and de-icing

Short pauses for de-icing are normal. A fault code is not. Use Vaillant aroTHERM not heating and the error codes pillar if one shows.

Talk to your installer

Vaillant’s handover guide asks owners not to change the detailed control settings the installer set. If a room is always cold, ask the installer to check the radiator size against that room’s heat loss and the heat curve. For the non-brand version of this guide, see radiators not getting hot with a heat pump.

Use the chat above to ask a question about your heat pump. We do not pass your details on to installers.

FAQs

Why are my radiators only warm with a Vaillant heat pump?

Because the water is cooler than on a boiler. Vaillant’s aroTHERM plus handover guide gives 35 to 55°C in the heating system against 60 to 70°C for a traditional boiler and says radiators will feel cooler to touch but are sized to keep each room warm. Judge it by the room temperature over a few hours, not by how hot the panel feels.

Do I need bigger radiators for an aroTHERM?

It depends on your home. Vaillant’s homeowner FAQs say the installer should carry out a room-by-room heat loss calculation and may recommend replacing radiators and that the pipework needs to allow good flow. Energy Saving Trust notes that radiators sized for a boiler may not be big enough at heat pump temperatures. If one room is always cold, ask your installer to check the radiator against the heat loss for that room.

Can I turn the flow temperature up?

Vaillant’s handover guide asks owners not to change the detailed settings the installer set, because they affect how the heat pump and heating system work. The heat curve is an installer-level setting on the system control. Vaillant also says the lower the flow temperature, the more efficient the system. Talk to your installer before changing it. See Vaillant heat curve settings.

What comfort and set-back temperatures does Vaillant suggest?

Vaillant’s handover guide gives an example: a comfort temperature of 21°C with a set-back 3 or 4°C lower, so 18 or 17°C. It also says heat pump systems should not be turned off completely, because a cold house takes more energy to warm up again. Treat that as a starting point, not a rule for every home.

Sources we checked

This is general guidance only. For faults or anything electrical, please contact a qualified heat pump engineer or Vaillant.