Noise reduction mode makes a Vaillant heat pump run more quietly by limiting compressor speed and adjusting the fan. The catch is less output while it’s active.
Where it’s set
- sensoCOMFORT: MENU | SETTINGS | Installer level | Noise reduction mode sets the time programme. A symbol shows on the basic display while it’s active.
- VRC 700: the installer setting “Noise reduction operation” (time periods).
- Indoor unit without a system control: “Compr. noise reduct.” 40 to 60 % (factory 40 %).
- It can’t be changed from the myVAILLANT app.
How much output you lose
On the indoor unit without a system control, compressor noise reduction is adjustable from 40 to 60 % (factory 40 %). Less compressor speed means less heating output while the mode is active. The held English manuals do not give kilowatt output figures for later 8.1 or pro outdoor units.
Is it costing me?
Possibly, in cold weather. Less output can mean longer runs, higher flow temperatures or back-up heater use. Keep the quiet window as short as practical, for example overnight if you’re close to neighbours.
Noise rules in England
From 29 May 2025, the 1 m boundary rule for permitted development was removed. Instead the unit must meet the MCS 020(a) sound calculation: no more than 37 dB at the assessment point 1 m outside a neighbour’s habitable-room window or door. Scotland and Wales have their own rules, so check with your local planning authority.
Common noises
- Night-time drone: the compressor at high speed. Check flow temperature and quiet mode times.
- Whoosh during defrost: normal.
- Rattles from the feet or casing: an installer job.
FAQ
Can I set quiet mode myself?
On sensoCOMFORT it’s at installer level, so ask your installer to set the times.
Can I change the percentage myself?
The 40 to 60 % compressor noise-reduction range is an indoor-unit setting when no system control is connected. With a sensoCOMFORT, the installer sets a noise-reduction time programme.
Related guides
Safety first
Owners can safely check pressure, valves, the controller and the outdoor unit from outside. Anything involving refrigerant, electrics, opening the unit or resetting internal cut-outs is a job for a qualified engineer. aroTHERM plus and aroTHERM pro units use R290, so refrigerant work needs an engineer competent with flammable refrigerants.
Still stuck?
Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.
Independent guide, not affiliated with or endorsed by Vaillant.