Viessmann Vitocal 200-A ie: Owner Overview

The Vitocal 200-A ie (“intelligent energy”) is Viessmann’s 2026 monobloc air source Heat Pump. It runs on One Base software and natural refrigerant R290 (propane). It shares the name “200-A” with an older Vitocal 200-A, so always check the data plate before using a manual.

Key figures

These come from the Vitocal 200-A ie datasheet 6257243 (October 2026). Viessmann’s product page and launch news give some slightly different, rounded figures, so use the datasheet or your installer’s paperwork for your own system.

  • Sizes: 06, 08, 10 and 12, with outputs from 1.5 to 12.8 kW across the range. At −7 °C outside and 35 °C flow the rated heating output is 5.46, 6.78, 8.70 and 9.72 kW.
  • Flow temperature: up to 75 °C, and up to 70 °C when it is −10 °C outside.
  • Outdoor temperatures: in heating mode the refrigerant circuit can start at outside temperatures down to −20 °C and switches off at −25 °C.
  • Refrigerant: R290, 1 kg on sizes 06 and 08 and 1.4 kg on sizes 10 and 12.
  • Sound power at ErP point C: 48, 49, 53 and 54 dB(A). Low-noise mode stage 2: 53, 53, 58 and 58 dB(A).
  • Outdoor unit: 1140 mm wide and 530 mm deep; 808 mm high and 93 kg (06, 08) or 1008 mm high and 118 kg (10, 12).
  • Cascades: Viessmann’s launch news says up to four units can work together, up to 48 kW. Its product page says Viessmann must commission cascade systems.

Indoor parts

The circulation pump and heater sit in the outdoor unit. Indoors you may have a unit with integrated hydraulics, one with a built-in hot water cylinder, or the compact Universal Controller (45 × 40 × 13.5 cm) when the pipework is fitted on site.

Fault messages

The 200-A ie uses One Base messages such as F.74 (system pressure too low). Its service book names different modules and terminals from older One Base models, so do not mix manuals from other generations.

FAQ

Is the Vitocal 200-A ie the same as the older Vitocal 200-A?

No. It shares the name but uses newer One Base electronics and its own 2026 service book. Use the manual that matches your data plate.

Can the Vitocal 200-A ie work with my existing radiators?

Viessmann says its flow temperature of up to 75 °C makes it suited to modernising existing homes, so radiators or underfloor heating can often stay. Your installer’s heat loss survey decides.

What to tell your installer

  • That you have a Vitocal 200-A ie, its size and the type from the data plate.
  • Any message number and text on the display or in ViCare.
  • Your system pressure reading.
  • When the problem started.

Manual references

Page numbers refer to the page printed in the manual unless marked as a PDF page. Check the manual that matches your data plate.

  • Viessmann datasheet Vitocal 200-A ie, 6257243 (10/2026): specification, PDF p5–7. Official PDF
  • Viessmann UK: Vitocal 200-A ie product page (retrieved 15 Nov 2026). Official page
  • Viessmann UK: Vitocal 200-A ie launch news, 23 June 2026 (retrieved 15 Nov 2026). Official page
  • Viessmann service instructions 6268114 (8/2026), monoblock heat pumps with One Base Intelligence, system configuration and diagnostics: F.74, PDF p70. Official PDF

Related guides

Safety first

The Vitocal 200-A ie uses flammable R290 refrigerant. Owners can use the display and ViCare and check the pressure gauge. Covers, refrigerant and electrical work are for a qualified engineer only.

Still stuck?

Ask the Heat Pump Assistant with your model, controller and what your screen shows, and you’ll get an answer tailored to your system. If it’s time for a check-up or a fault needs hands-on attention, Book a Service. You can also browse all our Help Guides.

Independent guide, not affiliated with or endorsed by Viessmann.