Short answer
A 7H code means your Daikin Altherma has detected too little water flowing through it. The most common causes are a closed valve, air in the system, low water pressure or a blocked filter. You can safely check the pressure gauge and make sure radiators and valves are open. If the code comes back, an engineer should check the filter, pump and flow sensor.
What the 7H error means
Your heat pump needs a minimum amount of water moving through it to work safely. If the flow sensor reads less than that, the unit shows a 7H code and stops heating to protect itself. Daikin’s installer reference guides publish minimum flow figures, and the rows differ by family and operation. On the Altherma 3 M 04–08 book the domestic-hot-water row (25 l/min) is higher than heating defrost (12 l/min). Other air-source books often publish a single minimum that must be guaranteed, including during defrost or backup-heater operation. The 7H-06 guide has the family table.
7H sub-codes explained
| Code | When it appears | How it resets |
|---|---|---|
| 7H-01 | Low flow detected during operation | Resets automatically |
| 7H-04 | Low flow mainly during hot water heating, after repeated 7H-01 resets | Manual reset from the controller |
| 7H-05 | Low flow mainly during space heating, after repeated 7H-01 resets | Manual reset from the controller |
| 7H-06 | Low flow mainly during cooling or defrost | Manual reset from the controller |
| 7H-07 | Pump de-blocking routine running | Normally clears itself |
These details come from a Daikin Altherma 3 service manual. The exact number of automatic resets before a manual reset is needed can vary between models, so check your own manual.
Common causes of a 7H code
Daikin’s service manual lists the checks in this order:
- A closed stop valve in the water circuit
- Air in the water circuit
- Water flow too low for the system
- Water pressure too low
- No bypass fitted where one is needed
- A dirty filter in the shut-off valve
- A dirty or faulty magnetic filter or dirt separator
- A faulty water flow sensor
- A faulty 3-way valve
- A faulty water pump
Only the first few are things an owner can look at. The rest need an engineer.
What you can safely check
1. Read the water pressure
Read the pressure on the controller or gauge while the system is cold. On many Altherma models Daikin’s documents give a range of about 1 to 2 bar, but check the figure for your model. If it is low, see our guide to Daikin Altherma water pressure. Only top up if your installer has shown you how and your manual allows it.
2. Check radiators and zone valves are open
If lots of radiator valves or zones are shut, there may not be enough open circuit for the water to flow. This is common in spring and autumn when people turn radiators off room by room.
3. Think about recent work
A 7H code soon after a new radiator, a drained system or a service often points to air or a valve left closed. Tell whoever did the work.
4. Look for leaks
Check around the indoor unit, the cylinder, radiators and the pressure relief pipe for drips or damp. A pressure drop with a leak needs an engineer.
5. Reset once
If the code needs a manual reset, follow your user guide once. If it comes back, stop and call an engineer.
Leave these to an engineer: bleeding air from inside the unit, cleaning the filter in the shut-off valve, opening the magnetic filter and any work on the pump, flow sensor or 3-way valve. These involve isolating and draining water and sometimes removing covers.
Why 7H often shows in cold weather
Defrost needs a higher minimum flow than normal heating. A system that only just has enough flow for heating can fall short during defrost, which is why 7H-06 is linked to defrost. Read more in our Daikin Altherma defrost cycle guide.
When to call an engineer
Call a qualified heat pump engineer if:
- the 7H code returns after one reset
- the pressure keeps dropping or you have to top up often
- you see water leaking
- the pressure is fine and all valves are open but the code remains
An engineer can check the flow reading, clean the filters, purge air properly and test the pump and flow sensor. Regular servicing helps prevent repeat faults. See our guide to Daikin Altherma filter cleaning.
FAQs
What does 7H-01 mean on a Daikin Altherma?
7H-01 means the heat pump has detected low water flow during operation. It resets automatically, but if it keeps happening the unit can move to 7H-04, 7H-05 or 7H-06, which need a manual reset.
Can low water pressure cause a 7H error?
Yes. Low pressure is one of the causes Daikin lists. A closed valve, air or a blocked filter can cause the same code even when the pressure is normal.
Can I clean the Daikin Altherma filter myself?
Cleaning the filter means isolating and draining part of the system. Unless your installer has shown you how and your manual covers it, leave it to an engineer.
Why does 7H-06 happen during defrost?
Defrost needs more water flow than normal heating. A system with marginal flow can pass in heating mode but fail during defrost.
Should I keep resetting a 7H code?
No. Reset once. If the code comes back, the cause needs finding. Running a heat pump with poor flow can stress the system.