Last reviewed: November 2026. Help for Daikin Altherma owners.
Short answer
If your Daikin Altherma is not heating, first check the controller for an error code. Then make sure space heating is on and set to heating mode. Check that holiday mode or a schedule is not holding the temperature down. Check the water pressure too. The heat pump also pauses heating while it heats hot water or defrosts, which is normal. If there is an error code, low pressure that keeps dropping or anything electrical, call a qualified engineer.
Quick checklist
- Is there an error code on the controller?
- Is space heating switched on?
- Is the operation mode set to heating, not cooling?
- Is holiday mode on, or is a schedule lowering the temperature?
- Is the room thermostat set high enough and working?
- Is the water pressure in the normal range?
- Is the heat pump heating hot water or defrosting right now?
- Are radiators or underfloor zones open?
Each check is explained below. Menu names vary between models and controllers, so use your user guide alongside this page.
1. Check for an error code
Look at the controller and the app for a warning symbol or code. If there is one, look it up in our Daikin Altherma error codes guide. Common ones when heating stops are 7H water flow codes and U4-00 communication faults.
2. Make sure heating is on and in the right mode
Check space heating has not been switched off, for example over summer. If your system can cool, check the operation mode is heating or automatic rather than cooling. Some systems are also set by the installer to stop space heating above a certain outdoor temperature. If the heat pump will not heat on a mild day, this may be why. Treat this as something to confirm with your installer, as it depends on your setup.
3. Check schedules and holiday mode
A weekly schedule may be holding the temperature low at certain times. Daikin’s guides explain that a manual change only lasts until the next scheduled action. Also check holiday mode has not been left on.
4. Check the room thermostat
If a room thermostat controls the heat pump, check its set temperature, its batteries if it is wireless and where it is fitted. A thermostat in a warm room, or next to a heat source, can switch heating off while the rest of the house is cold. A lost connection to a thermostat or adapter can show as a U8 code. See our room thermostat guide.
5. Check the water pressure
Read the pressure on the controller or gauge when the system is cold and compare it with your manual. Low pressure can cause flow problems and stop heating. See Daikin Altherma water pressure. If the pressure keeps dropping, call an engineer, as there may be a leak.
6. Is it a normal pause?
Hot water heating
Daikin explains that while the heat pump heats hot water it may not be able to heat your home at the same time. Powerful operation can cause longer heating interruptions. If your radiators go cool for a while and then warm up again, check whether the tank was heating. Moving hot water heating to overnight helps. See hot water schedules.
Defrost
In cold, damp weather the outdoor unit melts ice off its coil from time to time. Heating pauses briefly and you may see steam. This is normal. See our defrost cycle guide.
7. Check radiators and the weather curve
Heat pumps run radiators cooler than a gas boiler, so they can feel only warm while still heating the room. That is by design. If rooms do not reach temperature:
- check radiator valves and underfloor zones are open
- bleed radiators only if you know how. Check the pressure afterwards, as bleeding lowers it
- raise the weather curve offset by one step. See our weather curve guide
See also radiators not getting hot and house still cold.
8. Look at the outdoor unit
From the outside only, check the fan is not blocked by leaves, snow or ice build up. Clear loose debris by hand. Never chip ice off the fins or pour hot water on them. If the unit is completely silent and dark, check your consumer unit for a tripped breaker. If a breaker trips again, leave it off and call an electrician or engineer.
After a power cut
If heating stopped after a power cut, see our guide to a Daikin Altherma after a power cut.
When to call an engineer
Call a qualified heat pump engineer if:
- there is an error code that returns after one reset
- the water pressure keeps dropping or you see a leak
- a breaker trips more than once, or you smell burning
- the outdoor unit is iced solid and not defrosting
- your home is cold and none of the checks above help
If anyone in the home is vulnerable and it is cold, ask for an urgent visit. If your system is under warranty, contact your installer first.
FAQs
Why is my Daikin Altherma running but not heating the house?
Common reasons are a low weather curve, a schedule or thermostat holding the temperature down, hot water heating taking priority, a defrost cycle or closed radiators. An error code or low pressure can also stop heating.
Why do my radiators go cold for a while and then warm up again?
This is often the heat pump heating hot water or defrosting. Daikin explains that space heating may pause while the tank heats up.
Should radiators feel hot with a heat pump?
Not as hot as with a gas boiler. Heat pumps run at lower water temperatures, so radiators often feel warm rather than hot while still heating the room.
What should I check first if my heat pump stops heating?
Check the controller for an error code first. Then check heating is on, the mode, schedules and holiday mode, the thermostat and the water pressure.
When should I call an engineer?
Call an engineer if an error code returns, the pressure keeps dropping, a breaker trips or your home stays cold after the basic checks.