Short answer
Heat pump radiators often feel cooler than old boiler radiators even when they are doing their job, because the water is cooler. If rooms will not come up to temperature, check for an error code, read the water pressure against your manual, look at the outdoor unit and give the system time after a setback. Daikin says radiators need a higher leaving water temperature than underfloor heating, and that you should only adjust leaving water settings if there is a problem. Leave emitter-type and installer settings to your installer.
Cooler radiators are often normal
A heat pump is designed to run at a lower water temperature than a typical gas boiler. The radiators may feel only warm to the touch even when the room is at the set temperature. Energy Saving Trust makes the same point in its efficiency guide: radiators that were fine on a hot boiler may not feel the same when the water is cooler, which is usual on a heat pump.
Judge the result by the room temperature over a few hours, not by whether the panel is as hot as it was on a boiler.
If rooms will not come up to temperature
- Write down any error or alarm code and open the brand error-code guide.
- Check water pressure against your own manual. See heat pump water pressure.
- Look at the outdoor unit: blocked airflow or thick ice will cut the heat it can deliver. See iced up.
- Give the system time after a setback. Heat pumps, especially with slower emitters, do not recover like a hot boiler. See should I leave my heat pump on all the time?.
- Keep radiator valves open as the installer designed the system.
What to leave to your installer
Daikin’s Altherma 3 user guides say to set the desired leaving water temperature in accordance with the heat emitter type: underfloor heating is designed for a lower leaving water temperature than radiators. They also say only to adjust leaving water settings if there is a problem. Weather-dependent curves are the usual way a well set-up system gives a bit more heat as the outdoor temperature falls.
For Daikin detail, see running an Altherma with radiators, radiators not getting hot and the weather compensation curve guide. For Vaillant, see heat curve settings. Do not go looking for an installer PIN to change emitter type yourself.
Use the chat above to ask a question about your heat pump. We do not pass your details on to installers.
FAQs
Why are my radiators only lukewarm?
Heat pumps usually send cooler water than a traditional boiler. Energy Saving Trust notes that boiler radiators were often designed around much hotter water, and that a heat pump typically runs cooler. A radiator that feels milder than it used to can still be heating the room. Feel whether the room is coming up to the set temperature, not just whether the panel is scalding.
Should I turn the leaving water temperature up?
Only if your manual and installer guidance say there is a problem to fix. Daikin’s Altherma 3 user guides say to set leaving water temperature to suit the emitter type, that radiators need warmer water than underfloor heating, and that you should only adjust leaving water settings if there is a problem. A small change to the weather curve is often the better first step, and is best done with your installer if you are unsure.
Can closed radiator valves cause a fault?
Closing several rooms can reduce flow and lead to errors on some systems. Leave valves as the installer designed them unless you have been shown a safe change. If a low-flow or pressure code is showing, write it down and use the brand error-code guide.
What should I check before I call an engineer?
Write down any error code, read the water pressure against your manual, see whether some rooms are warmer than others, check the outdoor unit is clear and give the system time to recover after a deep setback. The Daikin-specific page is radiators not getting hot with a Daikin Altherma.