The letters in the middle of a Samsung EHS code tell you which family you have. AE080BXYDEG is an R32 Mono outdoor, AE260RNWMEG is a tank-integrated hydro unit, and AE160MXTPEH is TDM Plus — they are not three names for the same heat pump.
A typical outdoor code such as AE080BXYDEG/EU starts with AE, then a size class (080, 120 or 140 in the R32 Mono book), then a family string (BXYD here), then a suffix (EG or GG) and often /EU. Match the manual to that full string.
R32 Mono: BXYDEG is single-phase, BXYDGG is three-phase
Installation manual DB68-11904A-05 is titled for AE***BXYDEG and AE***BXYDGG and lists AE080, AE120 and AE140. Its specification page (printed page 6) gives:
| Outdoor code | Power supply | R32 charge | Net / gross weight |
|---|---|---|---|
| AE080BXYDEG | 1-phase, 220–240 V AC, 50 Hz | 2,700 g | 126 / 146 kg |
| AE120BXYDEG or AE140BXYDEG | 1-phase, 220–240 V AC, 50 Hz | 3,300 g | 137 / 157 kg |
| AE080BXYDGG | 3-phase, 380–415 V AC, 50 Hz | 2,700 g | 126 / 146 kg |
| AE120BXYDGG or AE140BXYDGG | 3-phase, 380–415 V AC, 50 Hz | 3,300 g | 137 / 157 kg |
The same page lists leaving-water temperature as 15–70°C for heating and 5–25°C for cooling, and an operating range of −30 to 43°C (heating) and 10–46°C (cooling). The wiring chapter has separate 1-phase and 3-phase supply tables. Those electrical rows are for an electrician reading this book, not a fuse size to pick from the web.
RNW tanks and MIM-E03, from the Mono KEYMARK table
KEYMARK is the European heat-pump certification mark. The Mono outdoor manual prints registered pairs on pages 56–57:
| Outdoor | Indoor or kit | Registration |
|---|---|---|
| AE080BXYDEG/EU | AE200RNWMEG/EU | 011-1W0549 |
| AE080BXYDEG/EU | AE260RNWMEG/EU | 011-1W0548 |
| AE080BXYDEG/EU | Space heating only, MIM-E03EN or MIM-E03CN | 011-1W0547 |
| AE080BXYDGG/EU | AE260RNWMGG/EU | 011-1W0548 |
| AE120BXYDEG/EU | AE200RNWMEG/EU | 011-1W0552 |
| AE120BXYDEG/EU | AE260RNWMEG/EU | 011-1W0551 |
| AE120BXYDEG/EU or AE140BXYDEG/EU | Space heating only, MIM-E03EN or MIM-E03CN | 011-1W0550 |
| AE140BXYDEG/EU | AE200RNWMEG/EU | 011-1W0552 |
| AE140BXYDEG/EU | AE260RNWMEG/EU | 011-1W0551 |
Three-phase BXYDGG rows use the GG tank suffix (for example AE260RNWMGG), not RNWMEG. The same table also lists some DNX, DNW, DNZ and DNY indoor codes; those indoor manuals are not among the public files used here.
An older tank-hydro manual, DB68-08367A-07 (printed ENGLISH-73), has its own KEYMARK table. That table pairs AE***RXYDEG / AE***RXYDGG outdoors with AE***RNWMEG tanks. RXYD and BXYD are different outdoor codes in different books.
TDM Plus and older JXYDEH codes
Codes containing MXTPEH or MXTPGH, with a TNWTEH tank, belong to the TDM Plus manuals — see the TDM pairing guide. Codes containing JXYDEH belong to a separate mono outdoor manual, DB68-05387A-07.
A CNW indoor code such as AE260CNWMEG does not appear in the public tank-hydro or Mono outdoor manuals cited above, so no CNW pairing is listed here.
FAQ
Can AE080BXYDEG be paired with AE260RNWMEG?
Yes. The R32 Mono outdoor KEYMARK table lists AE080BXYDEG/EU + AE260RNWMEG/EU as registration 011-1W0548.
Is BXYDEG the same heat pump as BXYDGG?
They share the same Mono manual, leaving-water range, refrigerant charge and operating temperatures for a given size. Page 6 prints BXYDEG as 1-phase 220–240 V and BXYDGG as 3-phase 380–415 V. Read the full suffix before anyone sizes a supply.
What to tell your engineer
- The full outdoor and indoor or control-kit codes, including EG/GG or EN/CN suffixes.
- Whether you have an RNW or TNW tank unit, a MIM-E03 kit only, or another indoor family.
- The DB68 document number on any manual left with the system.
Manual references
Page numbers are those printed in the manual unless marked as a PDF page.
- Samsung EHS R32 Mono outdoor installation manual DB68-11904A-05 (AE***BXYDEG / AE***BXYDGG): specification p6; wiring tables p34; KEYMARK p56–57. Download R32 Mono outdoor manual DB68-11904A-05 (PDF)
- Samsung EHS Tank Integrated Hydro Unit installation manual DB68-08367A-07: KEYMARK table for RXYD + RNW pairs, ENGLISH-73. Download tank-hydro manual DB68-08367A-07 (PDF)
- Samsung EHS MIM-E03EN/CN R32 control kit installation manual DB68-08471A-09. Download MIM-E03 manual DB68-08471A-09 (PDF)
- Samsung EHS mono outdoor installation manual DB68-05387A-07 (AE***JXYDEH). Download JXYDEH mono outdoor manual DB68-05387A-07 (PDF)
- Samsung TDM outdoor IM DB68-07002A-14 and TDM PLUS tank IM DB68-08915A-04. Download TDM outdoor manual DB68-07002A-14 (PDF) / Download TDM PLUS tank manual DB68-08915A-04 (PDF)
Related guides
- Samsung TDM Plus Outdoor and Tank Pairing Guide
- Samsung EHS Error 201: Control Kit Matching Fault
- Samsung EHS Tank Hydro Unit Hot Water Guide
- Samsung MIM-E03 Control Kit and Wired Controller Guide
- Samsung Heat Pump Error Codes: EHS Owner Guide
Safety first
Owners can read the data plate. Electrical, refrigerant (R32) and pairing work is for a qualified F-gas engineer.
Still stuck?
Ask the Heat Pump Assistant. Include your brand, model or controller, and the full code or message on screen. If you need hands-on help, Book a Service. You can also browse all our Help Guides.
Independent guide, not affiliated with or endorsed by Samsung.